While there is an extensive number of studies on the development and evaluation of electromyography (EMG)- and force-based control interfaces for assistive devices, no studies have focused on testing these control strategies for the specific case of adults with Duchenne muscular dystrophy (DMD). This paper presents a feasibility study on the use of EMG and force as control interfaces for the operation of active arm supports for men with DMD. We have built an experimental active elbow support, with a threefold objective: 1) to investigate whether adult men with DMD could use EMG- and force-based control interfaces; 2) to evaluate their performance during a discrete position-tracking task; and 3) to examine users' acceptance of the control methods. The system was tested in three adults with DMD (21-22 years). Although none of the three participants had performed any voluntary movements with their arms for the past 3-5 years, all of them were 100% successful in performing the series of tracking tasks using both control interfaces (mean task completion time EMG: [Formula: see text] , force: [Formula: see text] ). While movements with the force-based control were considerably smoother in Subject 3 and faster in Subject 1, EMG based-control was perceived as less fatiguing by all three subjects. Both EMG- and force-based interfaces are feasible solutions for the control of active elbow supports in adults with DMD and should be considered for further investigations on multi-DOF control.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TNSRE.2016.2530762DOI Listing

Publication Analysis

Top Keywords

control interfaces
20
emg- force-based
16
force-based control
16
active elbow
12
control
10
elbow supports
8
supports men
8
duchenne muscular
8
muscular dystrophy
8
feasibility study
8

Similar Publications

Background: Sepsis, a critical global health challenge, accounted for approximately 20% of worldwide deaths in 2017. Although the Sequential Organ Failure Assessment (SOFA) score standardizes the diagnosis of organ dysfunction, early sepsis detection remains challenging due to its insidious symptoms. Current diagnostic methods, including clinical assessments and laboratory tests, frequently lack the speed and specificity needed for timely intervention, particularly in vulnerable populations such as older adults, intensive care unit (ICU) patients, and those with compromised immune systems.

View Article and Find Full Text PDF

Freestanding networked nanoparticle (NP) films hold substantial potential due to their high surface areas and customizable porosities. However, NPs with high surface energies and heterogeneous sizes or shapes present considerable challenges as they tend to aggregate, compromising their structural integrities. In this study, we report the scalable fabrication of ultrathin, bicontinuous, and densely packed carbon NP films via Pickering emulsion-mediated interfacial assembly.

View Article and Find Full Text PDF

Desired Color Diversity of Carbon Fiber with Excellent Environmental Super-Durability and Remarkable Flame Retardancy.

ACS Appl Mater Interfaces

January 2025

State Key Laboratory of New Textile Materials and Advanced Processing Technologies, College of Textile Science and Engineering, Wuhan Textile University, Wuhan 430200, P. R. China.

Carbon fiber (CF) has been widely used in aerospace, military, infrastructure, sports, and leisure fields owing to its excellent mechanical properties, superior corrosion and friction resistances, excellent thermal stability, and lightweight. However, the ultrablack appearance derived from the extremely strong absorption of light throughout the entire visible region makes it difficult to satisfy the aesthetic and pleasurable demands of the colorful world and limits their applications in a broader field. Herein, inspired by the , a double-layer ultrathin AlO/TiO composite structure was fabricated on CFs by the atomic layer deposition method.

View Article and Find Full Text PDF

Heavy metal-organic pollutants compound pollution at industrial legacy sites and have caused damage to the ecological environment and human health during recent decades. In view of the difficulty and high cost of post-contamination remediation, it is worth studying, and practically applying, cutoff walls to reduce the spread of pollution in advance. In this study, field-scale studies were carried out at e-waste dismantling legacy sites in Taizhou, Zhejiang Province of China, through the process of site investigation, numerical simulation, and cutoff wall practical application.

View Article and Find Full Text PDF

Electrochemical Glucose Sensor Based on Dual Redox Mediators.

Biosensors (Basel)

December 2024

Cofoe Medical Technology Co., Ltd., No. 816 Zhenghua Road, Changsha 410021, China.

Electrochemical glucose sensor holds significant promise for the monitoring of blood glucose levels in diabetic patients. In this study, we proposed a novel electrochemical glucose sensor based on 1,10-Phenanthroline-5,6-dione (PD)/Ru(III) as a dual redox mediator. The synergistic effect of PD and Ru(III) was utilized to efficiently facilitate the electron transfer between the enzyme-active center and the electrode.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!