Quantitative Magnetic Separation of Particles and Cells Using Gradient Magnetic Ratcheting.

Small

Department of Bioengineering, University of California, 420 Westwood Plaza, 5121 Engineering V, P.O. Box 951600, Los Angeles, CA, 90095-1600, USA.

Published: April 2016

Extraction of rare target cells from biosamples is enabling for life science research. Traditional rare cell separation techniques, such as magnetic activated cell sorting, are robust but perform coarse, qualitative separations based on surface antigen expression. A quantitative magnetic separation technology is reported using high-force magnetic ratcheting over arrays of magnetically soft micropillars with gradient spacing, and the system is used to separate and concentrate magnetic beads based on iron oxide content (IOC) and cells based on surface expression. The system consists of a microchip of permalloy micropillar arrays with increasing lateral pitch and a mechatronic device to generate a cycling magnetic field. Particles with higher IOC separate and equilibrate along the miropillar array at larger pitches. A semi-analytical model is developed that predicts behavior for particles and cells. Using the system, LNCaP cells are separated based on the bound quantity of 1 μm anti-epithelial cell adhesion molecule (EpCAM) particles as a metric for expression. The ratcheting cytometry system is able to resolve a ±13 bound particle differential, successfully distinguishing LNCaP from PC3 populations based on EpCAM expression, correlating with flow cytometry analysis. As a proof-of-concept, EpCAM-labeled cells from patient blood are isolated with 74% purity, demonstrating potential toward a quantitative magnetic separation instrument.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4958462PMC
http://dx.doi.org/10.1002/smll.201502120DOI Listing

Publication Analysis

Top Keywords

quantitative magnetic
12
magnetic separation
12
particles cells
8
magnetic ratcheting
8
based surface
8
magnetic
7
cells
6
based
5
separation
4
particles
4

Similar Publications

Background: Midfoot pain is common but poorly understood, with radiographs often indicating no anomalies. This study aimed to describe bone, joint and soft tissue changes and to explore associations between MRI-detected abnormalities and clinical symptoms (pain and disability) in a group of adults with midfoot pain, but who were radiographically negative for osteoarthritis.

Methods: Community-based participants with midfoot pain underwent an MRI scan of one foot and scored semi-quantitatively using the Foot OsteoArthritis MRI Score (FOAMRIS).

View Article and Find Full Text PDF

Magnetic resonance imaging (MRI) currently serves as the primary diagnostic method for glioma detection and monitoring. The integration of neurosurgery, radiation therapy, pathology, and radiology in a multi-disciplinary approach has significantly advanced its diagnosis and treatment. However, the prognosis remains unfavorable due to treatment resistance, inconsistent response rates, and high recurrence rates after surgery.

View Article and Find Full Text PDF

Contrast-enhanced mammography (CEM) has recently gained recognition as an effective alternative to breast magnetic resonance imaging (MRI) for assessing breast lesions, offering both morphological and functional imaging capabilities. However, the phenomenon of background parenchymal enhancement (BPE) remains a critical consideration, as it can affect the interpretation of images by obscuring or mimicking lesions. While the impact of BPE has been well-documented in MRI, limited data are available regarding the factors influencing BPE in CEM and its relationship with breast cancer (BC) characteristics.

View Article and Find Full Text PDF

The influence of different pore sizes on the compressive strength and elastic modulus of recycled concrete is an important issue in the academic circle. Aiming at this problem, a quantitative characterization model of the compressive strength and elastic modulus of recycled concrete based on pore grading was established in this paper. The compressive strength, elastic modulus, porosity and distribution of pore size of recycled concrete were measured by a concrete test and nuclear magnetic resonance technology, and the influences of different pore sizes on the compressive strength and elastic modulus of recycled concrete were analyzed, and the rationality of the quantitative characterization model was verified.

View Article and Find Full Text PDF

Rising temperatures due to climate change may affect the quality of open-field cultivated processing tomatoes by altering the nutrient content. Bioinoculants are growing in popularity as a nature-based strategy to mitigate these environmental stresses. Untargeted quantitative NMR spectroscopy was leveraged to characterize the metabolome of tomato fruits exposed to abiotic stress during the year 2022, which was marked by unexpected high temperatures and low rainfall compared to the year 2021 with average conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!