Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Membrane-based devices typically used for serum protein binding determination are not fully applicable to highly lipophilic compounds because of nonspecific binding to the device membrane. Ultracentrifugation, however, completely eliminates the issue by using a membrane-free approach, although its wide application has been limited. This lack of utilization is mainly attributed to 2 factors: the high cost in acquiring and handling of radiolabeled compounds and low assay throughput owing to the difficulties in process automation. To overcome these challenges, we report a high-throughput workflow by cassette ultracentrifugation of nonradiolabeled compounds followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Twenty compounds with diverse physicochemical and protein binding properties were selected for the evaluation of the workflow. To streamline the working process, approaches of matrix balancing for all the samples for LC-MS/MS analysis and determining free fraction without analytical calibration curves were adopted. Both the discrete ultracentrifugation of individual compounds and cassette ultracentrifugation of all the test compounds followed by simultaneous LC-MS/MS analysis exhibited a linear correlation with literature values, demonstrating respectively the validity of the ultracentrifugation process and the cassette approach. The cassette ultracentrifugation using nonradiolabeled compounds followed by LC-MS/MS analysis has greatly facilitated its application for high-throughput protein binding screening in drug discovery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0022-3549(15)00177-X | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!