This study sought to evaluate the dosimetric impact of tumor bed delineation variability (based on clips, seroma or both clips and seroma) during external-beam partial breast irradiation (EB-PBI) planned utilizing four-dimensional computed tomography (4DCT) scans. 4DCT scans of 20 patients with a seroma clarity score (SCS) 3~5 and ≥5 surgical clips were included in this study. The combined volume of the tumor bed formed using clips, seroma, or both clips and seroma on the 10 phases of 4DCT was defined as the internal gross target volume (termed IGTVC, IGTVS and IGTVC+S, respectively). A 1.5-cm margin was added by defining the planning target volume (termed PTVC, PTVS and PTVC+S, respectively). Three treatment plans were established using the 4DCT images (termed EB-PBIC, EB-PBIS, EB-PBIC+S, respectively). The results showed that the volume of IGTVC+S was significantly larger than that of IGTVCand IGTVS. Similarly, the volume of PTVC+S was markedly larger than that of PTVC and PTVS. However, the PTV coverage for EB-PBIC+S was similar to that of EB-PBIC and EB-PBIS, and there were no significant differences in the homogeneity index or conformity index between the three treatment plans (P=0.878, 0.086). The EB-PBIS plan resulted in the lowest ipsilateral normal breast and ipsilateral lung doses compared with the EB-PBIC and EB-PBIC+S plans. To conclude, the volume variability delineated based on clips, seroma or both clips and seroma resulted in dosimetric variability for organs at risk, but did not show a marked influence on the dosimetric distribution.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4723953PMC

Publication Analysis

Top Keywords

clips seroma
24
tumor bed
12
seroma clips
12
dosimetric impact
8
impact tumor
8
bed delineation
8
delineation variability
8
variability based
8
external-beam partial
8
partial breast
8

Similar Publications

Purpose: In laparoscopic inguinal hernia repair, it is thought that the mesh can be displaced more in the enhanced-view totally extraperitoneal (eTEP) technique. The aim of this study was to compare eTEP and totally extraperitoneal (TEP) techniques without mesh fixation in terms of mesh displacement and hernia recurrence.

Methods: Between December 2022 and April 2023, 60 consecutive patients with unilateral inguinal hernia were randomized into two groups; eTEP group (n = 30) and TEP group (n = 30).

View Article and Find Full Text PDF

Purpose: Trocar site incisional hernia (TSIH) is a common complication of laparoscopic surgery. In the scientific literature there are few descriptions of methods or tools for its prevention. The aim of this report was to assess the effectiveness and safety of a prophylactic measure designed to lower rates of TSIH.

View Article and Find Full Text PDF

Purpose: The use of advanced energy devices for mastectomy and axillary lymph node dissection can reduce perioperative blood loss, seroma formation, and drainage duration/volume. Retraction using fiberoptic retractors can help visualize deep and narrow surgical fields. We aimed to compare the postoperative outcomes between single-incision breast-conserving surgery (SIBCS) and conventional breast-conserving surgery (CBCS) with axillary staging using advanced energy devices and conventional equipment, respectively.

View Article and Find Full Text PDF

How to increase the success rate in microsurgical free and pedicled flap reconstructions with intraoperative multistep ICG imaging: A case series with 400 consecutive cases.

J Plast Reconstr Aesthet Surg

October 2024

Department of Hand, and Plastic Surgery, Luzerner Kantonsspital, Lucerne, Switzerland; Department of Health Sciences and Medicine, University of Lucerne, Lucerne, Switzerland; Zentrum für Plastische Chirurgie, Pyramide Clinic, Zurich, Switzerland. Electronic address:

Background: Over the last decade, microsurgical soft-tissue transfer became the gold standard for various reconstructions throughout the body. Continuous improvement of instruments and surgical techniques, such as intraoperative indocyanine green angiography (ICG-A), allowed for a very high success rate. This study aimed to assess and validate the role of a standard intraoperative ICG-A in free and pedicled flap surgery to improve overall outcomes.

View Article and Find Full Text PDF

Minimal Access vs Conventional Nipple-Sparing Mastectomy.

JAMA Surg

October 2024

Department of Surgery, School of Medicine, Kyungpook National University, Kyungpook National University Chilgok Hospital, Daegu, Republic of Korea.

Importance: While nipple-sparing mastectomy (NSM) for breast cancer was only performed using the open method in the past, its frequency using endoscopic and robotic surgical instruments has been increasing rapidly. However, there are limited studies regarding postoperative complications and the benefits and drawbacks of minimal access NSM (M-NSM) compared with conventional NSM (C-NSM).

Objective: To examine the differences in postoperative complications between C-NSM and M-NSM.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!