Quality Indicators of Cervical Cytopathology Tests in the Public Service in Minas Gerais, Brazil.

Rev Bras Ginecol Obstet

Post-Graduate Program in Pharmaceutical Sciences, Department of Clinical Analysis, School of Pharmacy, Universidade Federal de Ouro Preto, Ouro Preto, MG, Brazil.

Published: February 2016

Objective: The objective of this study is to assess the performance of cytopathology laboratories providing services to the Brazilian Unified Health System (Sistema Único de Saúde - SUS) in the State of Minas Gerais, Brazil.

Methods: This descriptive study uses data obtained from the Cervical Cancer Information System from January to December 2012. Three quality indicators were analyzed to assess the quality of cervical cytopathology tests: positivity index, percentage of atypical squamous cells (ASCs) in abnormal tests, and percentage of tests compatible with high-grade squamous intraepithelial lesions (HSILs). Laboratories were classified according to their production scale in tests per year ≤ 5,000; from 5,001 to 10,000; from 10,001 to 15,000; and ≥ 15,001. Based on the collection of variables and the classification of laboratories according to production scale, we created and analyzed a database using Microsoft Office Excel 97-2003.

Results: In the Brazilian state of Minas Gerais, 146 laboratories provided services to the SUS in 2012 by performing a total of 1,277,018 cervical cytopathology tests. Half of these laboratories had production scales ≤ 5,000 tests/year and accounted for 13.1% of all tests performed in the entire state; in turn, 13.7% of these laboratories presented production scales of > 15,001 tests/year and accounted for 49.2% of the total of tests performed in the entire state. The positivity indexes of most laboratories providing services to the SUS in 2012, regardless of production scale, were below or well below recommended limits. Of the 20 laboratories that performed more than 15,001 tests per year, only three presented percentages of tests compatible with HSILs above the lower limit recommended by the Brazilian Ministry of Health.

Conclusion: The majority of laboratories providing services to the SUS in Minas Gerais presented quality indicators outside the range recommended by the Brazilian Ministry of Health.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10309496PMC
http://dx.doi.org/10.1055/s-0035-1571175DOI Listing

Publication Analysis

Top Keywords

minas gerais
16
quality indicators
12
cervical cytopathology
12
cytopathology tests
12
laboratories providing
12
providing services
12
production scale
12
services sus
12
tests
10
laboratories
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!