This study aimed to standardise an in-house real-time polymerase chain reaction (rtPCR) to allow quantification of hepatitis B virus (HBV) DNA in serum or plasma samples, and to compare this method with two commercial assays, the Cobas Amplicor HBV monitor and the Cobas AmpliPrep/Cobas TaqMan HBV test. Samples from 397 patients from the state of São Paulo were analysed by all three methods. Fifty-two samples were from patients who were human immunodeficiency virus and hepatitis C virus positive, but HBV negative. Genotypes were characterised, and the viral load was measure in each sample. The in-house rtPCR showed an excellent success rate compared with commercial tests; inter-assay and intra-assay coefficients correlated with commercial tests (r = 0.96 and r = 0.913, p < 0.001) and the in-house test showed no genotype-dependent differences in detection and quantification rates. The in-house assay tested in this study could be used for screening and quantifying HBV DNA in order to monitor patients during therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4750454PMC
http://dx.doi.org/10.1590/0074-02760150415DOI Listing

Publication Analysis

Top Keywords

hepatitis virus
12
in-house real-time
8
real-time polymerase
8
polymerase chain
8
chain reaction
8
cobas amplicor
8
amplicor hbv
8
hbv monitor
8
monitor cobas
8
cobas ampliprep/cobas
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?