Consistency of visual assessments of mammographic breast density from vendor-specific "for presentation" images.

J Med Imaging (Bellingham)

Dalhousie University, Faculty of Medicine, Department of Diagnostic Radiology, 1276 South Park Street, Room 3212, Dickson Building, Halifax, Nova Scotia B3H 2Y9, Canada; Nova Scotia Health Authority, Department of Diagnostic Imaging, 1276 South Park Street, Room 3212, Dickson Building, Halifax, Nova Scotia B3H 2Y9, Canada.

Published: January 2016

Discussions of percent breast density (PD) and breast cancer risk implicitly assume that visual assessments of PD are comparable between vendors despite differences in technology and display algorithms. This study examines the extent to which visual assessments of PD differ between mammograms acquired from two vendors. Pairs of "for presentation" digital mammography images were obtained from two mammography units for 146 women who had a screening mammogram on one vendor unit followed by a diagnostic mammogram on a different vendor unit. Four radiologists independently visually assessed PD from single left mediolateral oblique view images from the two vendors. Analysis of variance, intra-class correlation coefficients (ICC), scatter plots, and Bland-Altman plots were used to evaluate PD assessments between vendors. The mean radiologist PD for each image was used as a consensus PD measure. Overall agreement of the PD assessments was excellent between the two vendors with an ICC of 0.95 (95% confidence interval: 0.93 to 0.97). Bland-Altman plots demonstrated narrow upper and lower limits of agreement between the vendors with only a small bias (2.3 percentage points). The results of this study support the assumption that visual assessment of PD is consistent across mammography vendors despite vendor-specific appearances of "for presentation" images.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4748145PMC
http://dx.doi.org/10.1117/1.JMI.3.1.011004DOI Listing

Publication Analysis

Top Keywords

visual assessments
12
"for presentation"
12
breast density
8
presentation" images
8
vendors despite
8
mammogram vendor
8
vendor unit
8
bland-altman plots
8
vendors
7
assessments
5

Similar Publications

Background: Intraoperative ultrasound-guided breast-conserving surgery guarantees real-time direct visualization of tumor and resection margins. We compared surgical, oncologic, and cosmetic outcomes between intraoperative ultrasound-guided breast-conserving surgery and traditional (palpation- or wire-guided) surgery across all breast cancer lesion types.

Methods: This prospective observational cohort study was conducted at the Veneto Institute of Oncology between January 2021 and October 2022.

View Article and Find Full Text PDF

Objective: The potential of robot-assisted (RA) single-position (SP) lateral lumbar interbody fusion (LLIF) warrants further investigation. This study aimed to assess the efficacy of RA-SP-LLIF in improving both clinical and radiographic outcomes in patients undergoing lumbar spinal fusion surgery.

Methods: A total of 59 patients underwent either RA-SP-LLIF (n = 31 cases) or traditional LLIF (n = 28 cases).

View Article and Find Full Text PDF

Objective: The purpose of this study was to present a newly designed 3D-printed personalized model (3D PPM) of a radiofrequency needle guide with a maxillary fixation for gasserian ganglion (GG) puncture.

Methods: Implementation of 3D CT-guided radiofrequency therapy of the GG with and without use of 3D PPM was analyzed. The following parameters were assessed: radiation time, dose area product, air kerma reference point, pain severity during the puncture needle insertion, prosopalgia regression degree (according to visual analog scale) and the severity of facial numbness (according to the Barrow Neurological Institute scale) in the early postoperative period, and postpuncture complications.

View Article and Find Full Text PDF

Precise surgical resection of prostate cancer (PCa) is a significant clinical challenge due to the impact of positive surgical margins on postoperative outcomes. Fluorescence-guided surgery (FGS) enables real-time tumor visualization using fluorescent probes. In this study, we synthesized and evaluated an indocyanine green (ICG)-based PSMA-targeted near-infrared probe, , for intraoperative imaging of PCa lesions.

View Article and Find Full Text PDF

The purpose was to assess whether visual feedback of torque contributes to motor unit (MU) firing rate reduction observed during post-activation potentiation (PAP) of skeletal muscle. From 15 participants 23 MUs were recorded with intramuscular fine-wire electrodes from the tibialis anterior during isometric dorsiflexion contractions at 20% of maximum, with and without both PAP and visual feedback of torque. A 5s maximal voluntary contraction (MVC) was used to induce PAP, and evoked twitch responses were assessed before and after.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!