In this study, two analytical approaches were exploited for the resolution of binary mixtures of ciprofloxacin HCl (CIP) or norfloxacin (NOR) and phenazopyridine HCl (PHZ). In the first approach, the amplitudes of the first derivative of the ratio spectra were measured at 267 or 287 nm for CIP and at 268 or 291 nm for NOR. PHZ could be directly determined in the presence of CIP or NOR at 405 nm. The calibration graphs were rectilinear over the ranges of 1.0-16.0 µg/mL for CIP or NOR and 1.0-10.0 µg/mL for PHZ. In the second approach, an accurate, reliable and environmentally nontoxic micellar liquid chromatographic (MLC) method was developed. A good chromatographic separation was achieved using a 150 mm × 4.6 mm i.d., 5 µm particle size Spherisorb ODS-2 column. Eco-friendly mobile phase containing 0.12 M sodium dodecyl sulphate, 0.3% triethylamine and 6%n-butanol in 0.02 M orthophosphoric acid of pH 3.0 was pumped at a flow rate of 1 mL/min. Time programmed UV-detection was applied to allow sensitive determination of the studied drugs. The analytes were eluted without interferences in <10 min. Methocarbamol was used as an internal standard. The MLC method was found to be rectilinear over the concentration range of 0.5-20.0 μg/mL for CIP, NOR or PHZ. These optimized and validated methods were successfully applied for the simultaneous analysis of the studied drugs in their synthetic mixtures and co-formulated tablets. Moreover, the second method was further extended to the determination of these drugs in human urine with direct injection and without any pretreatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4890453PMC
http://dx.doi.org/10.1093/chromsci/bmw010DOI Listing

Publication Analysis

Top Keywords

derivative quotient
4
quotient spectrophotometry
4
spectrophotometry eco-friendly
4
eco-friendly micellar
4
micellar chromatographic
4
chromatographic approach
4
approach time-programmed
4
time-programmed uv-detection
4
uv-detection separation
4
separation fluoroquinolones
4

Similar Publications

Quotient Complex (QC)-Based Machine Learning for 2D Hybrid Perovskite Design.

J Chem Inf Model

January 2025

Division of Physics & Applied Physics, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371, Singapore.

With remarkable stability and exceptional optoelectronic properties, two-dimensional (2D) halide layered perovskites hold immense promise for revolutionizing photovoltaic technology. Effective data representations are key to the success of all learning models. Currently, the lack of comprehensive and accurate material representations has hindered AI-based design and discovery of 2D perovskites, limiting their potential for advanced photovoltaic applications.

View Article and Find Full Text PDF

A Health Risk Assessment of Workers Exposed to Organic Paint Solvents Used in the Korean Shipbuilding Industry.

Toxics

December 2024

Health and Safety Convergence Science Introduction, College of Health Science, Korea University, Seoul 02841, Republic of Korea.

In the shipbuilding industry, during the painting process, workers are exposed to various substances in paint, including organic solvents that can adversely affect their health. Most workplace exposures to organic solvents involve mixtures of organic compounds. Therefore, in this study, the hazard quotient (HQ) and hazard index (HI) were derived using data from the Workplace Environmental Monitoring Program in Korea for six organic solvents (xylene, n-butanol, ethylbenzene, isobutyl alcohol, toluene, and methylisobutyl ketone [MIBK]) commonly used in the steel shipbuilding industry.

View Article and Find Full Text PDF

Background: The association between physical fitness and autistic traits in adolescents remains under explored, especially in adolescents. Understanding this relationship can provide strategies to improve the quality of life of these people.

Objective: To identify the association between cluster characteristics derived from levels of self-perceived physical fitness and the occurrences of individual levels of autistic traits in Brazilian adolescents.

View Article and Find Full Text PDF

Emerging contaminants in estuarine sediments, such as bis(2-ethylhexyl) phthalate (DEHP) and titanium dioxide nanoparticles (nTiO), pose ecotoxicological risks that may be exacerbated by co-contamination. This study investigated the impacts of DEHP, nTiO, and their combinations at environmentally relevant concentrations (1, 10, and 100 μg/g) on the soil nematode Caenorhabditis elegans in estuarine-like sediment (14.25‰ salinity).

View Article and Find Full Text PDF

Cross-device and test-retest reliability of speech acoustic measurements derived from consumer-grade mobile recording devices.

Behav Res Methods

December 2024

Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.

In recent years, there has been growing interest in remote speech assessment through automated speech acoustic analysis. While the reliability of widely used features has been validated in professional recording settings, it remains unclear how the heterogeneity of consumer-grade recording devices, commonly used in nonclinical settings, impacts the reliability of these measurements. To address this issue, we systematically investigated the cross-device and test-retest reliability of classical speech acoustic measurements in a sample of healthy Chinese adults using consumer-grade equipment across three popular speech tasks: sustained phonation (SP), diadochokinesis (DDK), and picture description (PicD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!