A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

CLINICAL AND COST-EFFECTIVENESS OF INSULIN DELIVERY WITH V-GO(®) DISPOSABLE INSULIN DELIVERY DEVICE VERSUS MULTIPLE DAILY INJECTIONS IN PATIENTS WITH TYPE 2 DIABETES INADEQUATELY CONTROLLED ON BASAL INSULIN. | LitMetric

Objective: To compare two methods of delivering intensified insulin therapy (IIT) in patients with type 2 diabetes inadequately controlled on basal insulin ± concomitant antihyperglycemic agents in a real-world clinical setting.

Methods: Data for this retrospective study were obtained using electronic medical records from a large multicenter diabetes system. Records were queried to identify patients transitioned to V-Go(®) disposable insulin delivery device (V-Go) or multiple daily injections (MDI) using an insulin pen to add prandial insulin when A1C was >7% on basal insulin therapy. The primary endpoint was the difference in A1C change using follow-up A1C results.

Results: A total of 116 patients were evaluated (56 V-Go, 60 MDI). Both groups experienced significant glycemic improvement from similar mean baselines. By 27 weeks, A1C least squares mean change from baseline was -1.98% (-21.6 mmol/mol) with V-Go and -1.34% (-14.6 mmol/mol) with MDI, for a treatment difference of -0.64% (-7.0 mmol/mol; P = .020). Patients using V-Go administered less mean ± SD insulin compared to patients using MDI, 56 ± 17 units/day versus 78 ± 40 units/day (P<.001), respectively. Diabetes-related direct pharmacy costs were lower with V-Go, and the cost inferential from baseline per 1% reduction in A1C was significantly less with V-Go ($118.84 ± $158.55 per patient/month compared to $217.16 ± $251.66 per patient/month with MDI; P = .013).

Conclusion: Progression to IIT resulted in significant glycemic improvement. Insulin delivery with V-Go was associated with a greater reduction in A1C, required less insulin, and proved more cost-effective than administering IIT with MDI.

Abbreviations: A1C = glycated hemoglobin ANCOVA = analysis of covariance CI = confidence interval CSII = continuous subcutaneous insulin infusion FPG = fasting plasma glucose IIT = intensified insulin therapy LSM = least squares mean MDI = multiple daily injections T2DM = type 2 diabetes mellitus TDD = total daily dose.

Download full-text PDF

Source
http://dx.doi.org/10.4158/EP151182.ORDOI Listing

Publication Analysis

Top Keywords

insulin delivery
12
basal insulin
12
insulin
10
v-go® disposable
8
disposable insulin
8
delivery device
8
multiple daily
8
daily injections
8
patients type
8
type diabetes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!