A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A non-invasive magnetic resonance imaging-based model predicts portal venous pressure. | LitMetric

Objective: To establish a non-invasive model for the assessment of portal venous pressure (PVP) based on the magnetic resonance (MR) parameters.

Methods: In this prospective study, contrast-enhanced magnetic resonance imaging (MRI) scan was performed in 109 patients indicated for upper abdominal surgeries after their written consents were obtained, and intraoperative PVP measurements were completed in 92 patients. Altogether 17 patients were excluded for not undergoing surgery or unsuccessful catheterization. A linear model was constructed for estimating PVP levels in 56 patients and further validation was conducted in the other 36 patients.

Results: The PVP levels were significantly correlated with MR parameters, including splenic volume (SV), splenic venous diameter (SVD), liver/splenic volume ratio, portal venous diameter, hepatic diameter, portal venous cross-sectional area, ascites, varices and arterial portal shunts. A linear model was established as follows: PVP (mmHg) = 2.529 + 1.572 × SVD (mm) + 0.231 × SV/body mass index (× 10(4) cm(5) /kg) + 3.44 × aspartate aminotransferase-to-platelet ratio index. This model showed excellent accuracy in the detection of portal hypertension, with the area under the receiver operating characteristic curve (AUROC) of 0.945 (95% CI 0.867-1.000), with the sensitivity and specificity of 91.7% and 93.7%, respectively. The agreement analysis revealed that the predictive value using this formula closely reflected the patients' actual PVP level. Moreover, the validation confirmed the accuracy of this model for the assessment of portal hypertension [AUROC 0.935 (95% CI 0.856-1.000)].

Conclusions: The MRI-based formula has great potential for detecting portal hypertension. As a non-invasive measurement, it may be clinically accepted for the replacement of invasive modalities after further refinement.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1751-2980.12325DOI Listing

Publication Analysis

Top Keywords

portal venous
16
magnetic resonance
12
portal hypertension
12
portal
8
venous pressure
8
model assessment
8
assessment portal
8
linear model
8
pvp levels
8
venous diameter
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!