Correlation between scatter radiation dose at height of operator's eye and dose to patient for different angiographic projections.

Appl Radiat Isot

Radiological Sciences Center, Health Sciences Faculty, Tarapacá University, Av. General Velásquez 1775, postal code 1000000, Arica, Chile. Electronic address:

Published: November 2016

Studies have reported cases of radiation-induced cataract among cardiology professionals. In view of the evidence of epidemiological studies, the ICRP recommends a new threshold for opacities and a new radiation dose to eye lens limit of 20mSv per year for occupational exposure. The aim of this paper is to report scattered radiation doses at the height of the operator's eye in an interventional cardiology facility without considering radiation protection devices and to correlate these values with different angiographic projections and operational modes. Measurements were taken in a cardiac laboratory with an angiography X-ray system equipped with flat-panel detector. PMMA plates of 30×30×5cm were used with a thickness of 20cm. Measurements were taken in two fluoroscopy modes (low and normal, 15pulses/s) and in cine mode (15frames/s). Four angiographic projections were used: anterior posterior; lateral; left anterior oblique caudal (spider); and left anterior oblique cranial, with a cardiac protocol for patients weighing between 70 and 90kg. Measurements of phantom entrance dose rate and scatter dose rate were performed with two Unfors Xi plus detectors. The detector measuring scatter radiation was positioned at the usual distance of the cardiologist's eyes during working conditions. There is a good linear correlation between the kerma area product and scatter dose at the lens. Experimental correlation factors of 2.3, 12.0, 12.2 and 17.6μSv/Gycm2 were found for different projections. PMMA entrance dose rates for low and medium fluoroscopy and cine modes were 13, 39 and 282mGy/min, respectively, for AP projection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2016.01.013DOI Listing

Publication Analysis

Top Keywords

angiographic projections
12
scatter radiation
8
radiation dose
8
height operator's
8
operator's eye
8
left anterior
8
anterior oblique
8
entrance dose
8
dose rate
8
scatter dose
8

Similar Publications

Background And Objectives: Direct visualization of the aneurysmal neck and its related perforating arteries during microsurgical clipping of posterior communicating artery (PCoA) aneurysms with posterior projection or true PCoA aneurysms through the pterional approach may be difficult and complicated.

Methods: From January 2022 to January 2023, the clinical and angiographic information regarding PCoA aneurysms were retrospectively collected. Among them, 10 consecutive patients with PCoA aneurysms treated with microsurgical clipping via the subtemporal approach in our single institution were included.

View Article and Find Full Text PDF

NeCA: 3D Coronary Artery Tree Reconstruction from Two 2D Projections via Neural Implicit Representation.

Bioengineering (Basel)

December 2024

Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, UK.

Cardiovascular diseases (CVDs) are the most common health threats worldwide. 2D X-ray invasive coronary angiography (ICA) remains the most widely adopted imaging modality for CVD assessment during real-time cardiac interventions. However, it is often difficult for the cardiologists to interpret the 3D geometry of coronary vessels based on 2D planes.

View Article and Find Full Text PDF

STUDY OF ORBITAL NEOPLASMS BY MAGNETIC RESONANCE IMAGING PROCEDURE.

Georgian Med News

October 2024

2Tbilisi State Medical University, Clinical Professor, Tbilisi, Georgia.

The neoplasms of the organ of vision are characterized by significant polymorphism, which is due to the histological diversity of the structures in the eye socket. Almost all types of neoplasms described in humans are found in the orbit. The study aimed to determine the diagnostic value of magnetic resonance imaging in patients with tumors in the eyeball and the eye socket, as well as to determine the superiority of the MRI procedure compared to other instrumental methods of research.

View Article and Find Full Text PDF

Background: The angiography-derived non-hyperemic pressure ratio (angioNHPR) is a novel index of NHPR based on artificial intelligence (AI) that does not require pressure wires. We investigated the diagnostic accuracy of angioNHPR for detecting hemodynamically relevant coronary artery disease.

Methods And Results: In this retrospective single-center study, angioNHPR was assessed using the invasive NHPR as the reference standard.

View Article and Find Full Text PDF

Purpose: A case of frontal branch of the left middle meningeal artery (MMA) arising from the ophthalmic artery (OA).

Methods: A 73-year-old woman with vertigo underwent cranial magnetic resonance (MR) imaging and cranial MR angiography using a 1.5-Tesla scanner.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!