Aims: Manufacturers of implantable cardioverter defibrillators (ICDs) recommend that cell phones be maintained at a distance of ∼15 cm from the implanted device in order to avoid risk of dysfunction due to electromagnetic interference (EMI). Data relating to this issue are outdated and do not reflect modern technology. Our aim was to evaluate whether EMI is still an issue with contemporary ICDs and smartphones.

Methods And Results: Consecutive patients implanted with a wireless-enabled ICD were tested for potential interference with two models of recent 4G smartphones in conditions intended to maximize risk of EMI. A magnet effect (due to the phone speakers) was tested by placing the smartphones in the standby mode directly over the ICD generator. The presence of EMI artefacts on the real-time electrograms was evaluated by placing the smartphones in the standby, dialling, and operating modes directly over the generator casing and over the parasternal region in the vicinity of the ventricular lead. A total of 63 patients equipped with 29 different models of single, dual, or biventricular ICDs from five major manufacturers were included. None of the patients showed any evidence of interference with the smartphones during any of the 882 tests.

Conclusion: The risk of EMI between modern smartphones and contemporary ICDs is low. This is probably due to the filters incorporated in the ICDs and low emission by the phones, as well as the small size of the magnets in the smartphones tested.

Study Registration: NCT02330900 (http://www.clinicaltrials.gov).

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euv374DOI Listing

Publication Analysis

Top Keywords

electromagnetic interference
8
interference smartphones
8
smartphones contemporary
8
implantable cardioverter
8
cardioverter defibrillators
8
contemporary icds
8
risk emi
8
placing smartphones
8
smartphones standby
8
icds low
8

Similar Publications

Designing Carbon-Foam Composites via Molten-State Reduction for Multifunctional Electromagnetic Interference Shielding.

ACS Nano

January 2025

NanoScience Technology Center, Department of Materials Science and Engineering, Department of Chemistry, Renewable Energy and Chemical Transformation Cluster, The Stephen W. Hawking Center for Microgravity Research and Education, University of Central Florida, Orlando, Florida 32826, United States.

Advanced electromagnetic interference (EMI) shielding materials are in great demand because of the severe electromagnetic population problem caused by the explosive growth of advanced electronics. Besides superior EMI shielding properties, the mechanical strength of the shielding materials is also critical for some specific application scenarios (e.g.

View Article and Find Full Text PDF

NIR-II-excited off-on-off fluorescent nanoprobes for sensitive molecular imaging in vivo.

Nat Commun

January 2025

Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 1, Singapore, 117585, Singapore.

Strong background interference signals from normal tissues have significantly compromised the sensitive fluorescence imaging of early disease tissues with exogenous probes in vivo, particularly for sensitive fluorescence imaging of early liver disease due to the liver's significant uptake and accumulation of exogenous nanoprobes, coupled with high tissue autofluorescence and deep tissue depth. As a proof-of-concept study, we herein report a near-infrared-II (NIR-II, 1.0-1.

View Article and Find Full Text PDF

Enhancing IoT security in smart grids with quantum-resistant hybrid encryption.

Sci Rep

January 2025

Faculty of Mechanical and Electrical Engineering, Quzhou College of Technology, Quzhou, 324000, Zhejiang, China.

Integrating the Internet of Things (IoT) in smart grids has revolutionized the energy sector, enabling real-time data collection and efficient energy distribution. However, this integration also introduces significant security challenges, particularly data encryption. Traditional encryption algorithms used in IoT are vulnerable to various attacks, and the advent of quantum computing exacerbates these vulnerabilities.

View Article and Find Full Text PDF

Microgel-Guided MXene Assembly for High-Performance, Low-Solid Content Conductive Inks.

ACS Appl Mater Interfaces

January 2025

Department of Chemical Engineering, University of South Carolina, Columbia, South Carolina 29208, United States.

Rapid evolution of smart devices necessitates high-performance, lightweight materials for effective electromagnetic interference (EMI) shielding. TiCT MXene nanosheets are promising for such applications, yet the high solid content typically required for 3D-printable MXene inks limits their scalability and cost efficiency. In this study, we present an MXene-based ink with an ultralow solid content (0.

View Article and Find Full Text PDF

Babassu (Atallea sp.), a native palm tree from South America's Amazon produces bio-oil and biochar with significant potential for industrial applications. Babassu oil as a bio-based plasticizer is reported here for the first time to replace petrochemical alternatives in the production of conductive filaments for additive manufacturing purposes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!