Detecting bone marrow involvement (BMI) in lymphoma is important as it adversely affects stage. Bone marrow biopsy (BMB) remains the standard to detect BMI but is prone to sampling error. We retrospectively investigated whether (18)F-fluorodeoxyglucose positron emission tomography with computed tomography ((18)F-FDG-PET/CT) could identify BMI in patients with post-transplant lymphoproliferative disorder (PTLD) with sufficient accuracy in comparison with staging BMB. Twenty-five patients diagnosed with PTLD who underwent (18)F-FDG-PET/CT and BMB within one month were evaluated. Based on our criteria, six patients (24%) were considered positive for BMI on (18)F-FDG-PET/CT compared to one by BMB. Although we cannot completely exclude false positive results on (18)F-FDG-PET/CT, our data indicate a significantly higher sensitivity of (18)F-FDG-PET/CT compared to BMB (100% vs 17%) but similar specificity. These data confirm the high diagnostic performance of (18)F-FDG-PET/CT for detecting BMI, but prospective studies are needed to determine whether (18)F-FDG-PET/CT could indeed replace staging BMB in PTLD.

Download full-text PDF

Source
http://dx.doi.org/10.3109/10428194.2016.1140162DOI Listing

Publication Analysis

Top Keywords

bone marrow
16
marrow involvement
8
post-transplant lymphoproliferative
8
lymphoproliferative disorder
8
18f-fluorodeoxyglucose positron
8
positron emission
8
marrow biopsy
8
staging bmb
8
18f-fdg-pet/ct compared
8
compared bmb
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!