A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of the change in posterior corneal elevation and corneal biomechanical parameters after small incision lenticule extraction and femtosecond laser-assisted LASIK for high myopia correction. | LitMetric

Comparison of the change in posterior corneal elevation and corneal biomechanical parameters after small incision lenticule extraction and femtosecond laser-assisted LASIK for high myopia correction.

Cont Lens Anterior Eye

Key Myopia Laboratory of Chinese Health Ministry, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, No. 83, Fenyang Road, Shanghai 200031, China. Electronic address:

Published: June 2016

Purpose: To compare posterior corneal elevation (PCE) changes and corneal biomechanical changes post fematosecond laser-assisted laser in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE) procedures using the Pentacam system and the Ocular Response Analyzer (ORA).

Design: Retrospective observational case series study.

Method: 106 patients with bilateral myopia who underwent either FS-LASIK (56 patients) or SMILE (50 patients) were reviewed, only the right eye was used in the analysis. Inclusion criteria include a spherical equivalent of -6.00DS and completion of 12 months follow up. The main outcome evaluated was change in PCE at 3 months, 6 months and 12 months post-operation using the Pentacam system. Corneal biomechanical parameters were evaluated at 6 and 12 months with the ORA.

Results: PCE change at 3 and 6 months were not significantly different between the two procedures (p=0.064, p=0.109 respectively). At 12 months, PCE change was greater in FS-LASIK than SMILE (p=0.048). One-way ANOVA showed that for either procedure, the change in PCE did not differ at 3, 6 or 12 months post operation. CH and CRF values were reduced after both procedures, with FS-LASIK demonstrating a greater reduction in CRF than SMILE at 6 and 12 months (p=0.037 and p=0.001). Both CH and CRF reduction correlated with PCE increase at 6 and 12 months.

Conclusion: FS-LASIK demonstrated a greater increase in PCE than SMILE only at 12 months, as well as a greater reduction of CRF than SMILE. There were no significant differences in PCE change over time within either group.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clae.2016.01.007DOI Listing

Publication Analysis

Top Keywords

corneal biomechanical
12
pce change
12
months
10
posterior corneal
8
corneal elevation
8
biomechanical parameters
8
small incision
8
incision lenticule
8
lenticule extraction
8
pce
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!