A local Echo State Property through the largest Lyapunov exponent.

Neural Netw

UNIC, CNRS Gif sur Yvette, France.

Published: April 2016

Echo State Networks are efficient time-series predictors, which highly depend on the value of the spectral radius of the reservoir connectivity matrix. Based on recent results on the mean field theory of driven random recurrent neural networks, enabling the computation of the largest Lyapunov exponent of an ESN, we develop a cheap algorithm to establish a local and operational version of the Echo State Property.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neunet.2015.12.013DOI Listing

Publication Analysis

Top Keywords

echo state
12
state property
8
largest lyapunov
8
lyapunov exponent
8
local echo
4
property largest
4
exponent echo
4
state networks
4
networks efficient
4
efficient time-series
4

Similar Publications

Using magnetic resonance imaging (MRI) with radial scanning, images of intact rat lungs and rat lungs with pulmonary hypertension were obtained. The retrospective gating method was applied to construct images of rat lungs during inspiration and expiration phases. Lung volumes at both respiratory phases, relative tidal volume, and the percentage of lung lesions were calculated.

View Article and Find Full Text PDF

Highly efficient heteronuclear polarization transfer using dipolar-echo edited R-symmetry sequences in solid-state NMR.

Chem Sci

December 2024

State Key Laboratory of Catalysis, Dalian National Laboratory for Clean Energy, Dalian Institute of Chemical Physics, Chinese Academy of Sciences Zhongshan Road 457 Dalian 116023 China

In solid-state NMR, dipolar-based heteronuclear polarization transfer has been extensively used for sensitivity enhancement and multidimensional correlations, but its efficiency often suffers from undesired spin interactions and hardware limitations. Herein, we propose a novel dipolar-echo edited R-symmetry (DEER) sequence, which is further incorporated into the INEPT-type scheme, dubbed DEER-INEPT, for achieving highly efficient heteronuclear polarization transfer. Numerical simulations and NMR experiments demonstrate that DEER-INEPT offers significantly improved robustness, enabling efficient polarization transfer under a wide range of MAS conditions, from slow to ultrafast rates, outperforming existing methods.

View Article and Find Full Text PDF

Brief Report: Precision Language and Deletion of the "S" Word.

JTO Clin Res Rep

January 2025

Division of Hematology and Oncology, College of Medicine, University of Illinois Chicago, Chicago, Illinois.

Introduction: In 2021, the International Association for the Study of Lung Cancer (IASLC) published the IASLC Language Guide as guidance on preferred language and phrasing in oral and written communications, including presentations at conferences. This study analyzed presentations from the 2022 IASLC World Conference on Lung Cancer (WCLC) one year after implementation of the Language Guide to identify adoption rates of non-stigmatizing language and to determine correlations with presenter characteristics.

Methods: We downloaded 522 slide presentations from the IASLC WCLC 2022 conference attendee portal.

View Article and Find Full Text PDF

Differentiating intraparotid facial nerve schwannoma from other parotid tumors, particularly pleomorphic adenoma, is clinically crucial due to significant differences in treatment approaches. We report a case of a male patient in his 70s presenting with a left parotid mass. Magnetic Resonance Imaging (MRI) revealed a mass within the left parotid gland exhibiting the characteristic ``target sign''.

View Article and Find Full Text PDF

Comparison and calibration of MP2RAGE quantitative T1 values to multi-TI inversion recovery T1 values.

Magn Reson Imaging

January 2025

Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN, United States; Department of Computer Science, Vanderbilt University, Nashville, TN, United States; Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, United States; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, United States.

While typical qualitative T1-weighted magnetic resonance images reflect scanner and protocol differences, quantitative T1 mapping aims to measure T1 independent of these effects. Changes in T1 in the brain reflect structural changes in brain tissue. Magnetization-prepared two rapid acquisition gradient echo (MP2RAGE) is an acquisition protocol that allows for efficient T1 mapping with a much lower scan time per slab compared to multi-TI inversion recovery (IR) protocols.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!