Introduction: We evaluated analytical and clinical performances of IgG and IgM anticardiolipin (aCL) antibodies and anti-β2-glycoprotein I (a-β2GpI) antibodies and upper limit reference ranges (99th percentiles) in comparison with manufacturer's cutoff values with different commercial methods.

Methods: We assayed aCL and a-β2GpI in serum samples from 30 healthy individuals, 77 patients with antiphospholipid syndrome (APS) diagnosed according to the Sydney criteria, 51 patients with autoimmune diseases, eight patients with previous thrombotic events, six patients with other diseases, and 18 patients with infectious diseases, using ELISA Inova Diagnostics; EliA Phadia Laboratory Systems; CliA Zenit-RA; and CliA Bio-Flash.

Results: Anticardiolipin and a-β2GpI IgG and IgM immunoassays showed good analytic performances with both 99th percentile and manufacturer's cutoff reference values. Our results showed fair to moderate agreement among assays. In-house cutoff values gave significantly better performances only for a-β2GpI IgG with all the immunoassays analyzed with the exception of Inova CliA Bio-Flash where we obtained the same performances with in-house and manufacturer's cutoffs.

Conclusions: By guidelines, all laboratories are strongly advised to validate/verify the manufacturer's cutoff values. We recommend establishing low-positive, medium-/high-positive, and high-positive CliA IgG aCL and a-β2GpI ranges in order to help clinicians in the diagnosis and treatment of APS.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ijlh.12466DOI Listing

Publication Analysis

Top Keywords

manufacturer's cutoff
12
cutoff values
12
analytical clinical
8
igg igm
8
acl a-β2gpi
8
diseases patients
8
a-β2gpi igg
8
a-β2gpi
5
patients
5
clinical comparison
4

Similar Publications

Background: US tools to quantify hepatic steatosis have recently been made clinically available by different manufacturers, but comparative data on their consistency are lacking.

Objective: US tools to quantify hepatic steatosis have recently been made clinically available by different manufacturers, but comparative data on their consistency are lacking. The aim of our study was to compare the diagnostic consistency for evaluating hepatic steatosis by two different US techniques, hepatorenal index by B-mode Ratio and attenuation coefficient by attenuation imaging (ATI).

View Article and Find Full Text PDF

Biobased Polyesters with Ultrahigh UV Shielding and Water Degradation Derived from Multifunctional Tetracyclic Diesters.

Biomacromolecules

January 2025

Dalian Key Laboratory of Green Manufacturing Technology for Fine Chemicals Production, College of Environmental and Chemical Engineering, Dalian University, Dalian 116622, P. R. China.

The development of biobased polyesters with the combination of high UV shielding and degradability is a significant challenge. Herein, three 4-membered cyclic monomers containing two pyrrolidone and two furan rings were prepared by the aza-Michael addition of biobased bifuran diamine and dimethyl itaconate (DMI). They were available in melt polycondensation reactions with various diols to synthesize biobased polyesters.

View Article and Find Full Text PDF

Flow-Based Coronary Artery Bypass Graft Patency Metrics: Uncertainty Quantification Simulations to Guide Development.

Cardiovasc Eng Technol

January 2025

Transonic Systems Inc., 34 Dutch Mill Road, Ithaca, New York, 14850, USA.

Purpose: Over time, transit time flow measurement (TTFM) has proven itself as a simple and effective tool for intra-operative evaluation of coronary artery bypass grafts (CABGs). However, metrics used to screen for possible technical error show considerable spread, preventing the definition of sharp cut-off values to distinguish between patent, questionable, and failed grafts. The simulation study presented in this paper aims to quantify this uncertainty for commonly used patency metrics, and to identify the most important physiological parameters influencing it.

View Article and Find Full Text PDF

Quantum computers now encounter the significant challenge of scalability, similar to the issue that classical computing faced previously. Recent results in high-fidelity spin qubits manufactured with a Si CMOS technology, along with demonstrations that cryogenic CMOS-based control/readout electronics can be integrated into the same chip or die, opens up an opportunity to break out the challenges of qubit size, I/O, and integrability. However, the power consumption of cryogenic CMOS-based control/readout electronics cannot support thousands or millions of qubits.

View Article and Find Full Text PDF

N-Acetyltyrosine as a Biomarker of Parenteral Nutrition Administration in First-Tier Newborn Screening Assays.

Int J Neonatal Screen

December 2024

Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Hwy NE, S110-3, Atlanta, GA 30341, USA.

Parenteral nutrition (PN) is a nutrient solution administered intravenously (IV) to premature babies. PN causes elevations of some amino acids in blood samples that are also biomarkers used in newborn screening (NBS). Therefore, PN status must be annotated by clinicians on dried blood spot (DBS) cards to reduce NBS laboratory burdens associated with potential false results; however, NBS laboratories continue to receive DBSs with misannotated PN status.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!