Aims: Catheter ablation of atrial fibrillation (AF) in patients with heart failure (HF) can improve left ventricular (LV) function and HF symptoms. We aimed to investigate whether long-term maintenance of sinus rhythm impacts on hard outcomes such as stroke and death.
Methods And Results: An international multicentre registry was compiled from seven centres for consecutive patients undergoing catheter ablation of AF. Long-term freedom from AF was examined in patients with and without HF. The impact of maintaining sinus rhythm on rates of stroke and death was also examined. A total of 1273 patients were included: 171 with HF and 1102 without. Median follow-up was 3.1 years (IQR 2.0-4.3). The final procedure success rate was no different for paroxysmal AF (PAF) (78.7 vs. 85.7%, P = 0.186), but significantly different for persistent AF (57.3 vs. 75.8%, P < 0.001). Multivariate analysis showed that HF independently predicted recurrent arrhythmia [hazard ratio (HR) 1.7, 95% confidence interval (CI) 1.2-2.4, P = 0.002]. New York Heart Association class decreased from 2.3 ± 0.7 at baseline to 1.5 ± 0.8 at follow-up (P < 0.001). Left ventricular ejection fraction (LVEF) increased from 34.3 ± 9.0 to 45.8 ± 12.8% (P < 0.001). Recurrent AF was strongly predictive of stroke or death in HF patients (HR 8.33, 95% CI 1.86-37.7, P = 0.001).
Conclusion: Long-term success rates for persistent (but not paroxysmal) AF ablation are significantly lower in HF patients. Left ventricular function and HF symptoms were improved following ablation. In HF patients, recurrent arrhythmia strongly predicted stroke and death during follow-up.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/euv440 | DOI Listing |
Sci Rep
December 2024
School of Physical Education, Southwest Petroleum University, Chengdu, 610500, China.
Stroke is one of the leading causes of death in developing countries, and China bears the largest global burden of stroke. This study aims to investigate the relationship between different dimensions of physical activity levels and stroke risk using a nationally representative database. We performed a cross-sectional analysis using data from the China Health and Retirement Longitudinal Study (CHARLS) 2020.
View Article and Find Full Text PDFBAY 2413555 is a novel selective and reversible positive allosteric modulator of the type 2 muscarinic acetylcholine (M2) receptor, aimed at enhancing parasympathetic signaling and restoring cardiac autonomic balance for the treatment of heart failure (HF). This study tested the safety, tolerability and pharmacokinetics of this novel therapeutic option. REMOTE-HF was a multicenter, double-blind, randomized, placebo-controlled, phase Ib dose-titration study with two active arms.
View Article and Find Full Text PDFNat Commun
December 2024
Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD, USA.
Currently there are no effective treatments for an array of neurodegenerative disorders to a large part because cell-based models fail to recapitulate disease. Here we develop a reproducible human iPSC-based model where laser axotomy causes retrograde axon degeneration leading to neuronal cell death. Time-lapse confocal imaging revealed that damage triggers an apoptotic wave of mitochondrial fission proceeding from the site of injury to the soma.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
December 2024
Department of Cardiology, Angiology and Intensive Care Medicine, University Heart Center Lübeck, Lübeck, Germany.
Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.
Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.
World Neurosurg
December 2024
Department of Neurosurgery, Interdisciplinary Graduate School of Medicine and Engineering, University of Yamanashi, Chuo, Japan.
Background: Flow diverters (FDs) have been introduced for the management of large or giant cavernous carotid aneurysms (CCAs) in addition to conventional modalities, dramatically changing treatment strategies. The aim of this study was to examine the management of unruptured large/giant CCAs in Japan when FDs were being introduced using a nationwide survey.
Methods: 540 unruptured large/giant CCAs treated at neurosurgical teaching departments in Japan between 2012 and 2016 were retrospectively studied.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!