Purpose: The predictive performance of glomerular filtration rate (GFR) estimation equations based on cystatin C versus serum creatinine (SCr) values in critically ill patients was evaluated.

Methods: A retrospective observational study was performed in the medical intensive care unit (ICU) of a university hospital from October 2006 through September 2007. All consecutively admitted critically ill patients older than 18 years who stayed in the ICU for more than 48 hours with a urinary bladder catheter in place were included in the study. Data collected included SCr, cystatin C, serum albumin, blood urea nitrogen, and 24-hour urine creatinine clearance [Formula: see text] levels. The following equations were also used to determine the estimated GFR that was compared with the reference [Formula: see text] for all patients in the study: Arnal-Dade using cystatin C, Cockcroft-Gault using actual body weight, Cockcroft-Gault using ideal body weight, Jelliffe, Modification of Diet in Renal Disease (MDRD), and four-variable version MDRD (MDRD-4).

Results: This study included 241 measurements corresponding to 131 critically ill patients. The cystatin C-based equation underestimated [Formula: see text], whereas overestimation by every SCr-based formula was observed in the whole cohort and in the [Formula: see text] subgroup; MDRD-4 was the most biased equation in every analysis. There were no significant differences in precision, except for great variability in the subgroup with a [Formula: see text] of <60 mL/min/1.73 m(2), where the MDRD equation showed better results than the cystatin C-based equation (33.5% versus 38.9%). No equations fulfilled concordance requirements with [Formula: see text].

Conclusion: A retrospective observational study showed no evidence of superiority of a cystatin C-based equation over SCr-based equations to estimate the GFR in an ICU population.

Download full-text PDF

Source
http://dx.doi.org/10.2146/ajhp140852DOI Listing

Publication Analysis

Top Keywords

[formula text]
20
critically ill
16
ill patients
16
predictive performance
8
performance glomerular
8
glomerular filtration
8
filtration rate
8
estimation equations
8
equations based
8
based cystatin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!