The aim of this European Heart Rhythm Association (EHRA) survey was to collect data on the use of wearable cardioverter-defibrillators (WCDs) among members of the EHRA electrophysiology research network. Of the 50 responding centres, 23 (47%) reported WCD use. Devices were fully reimbursed in 17 (43.6%) of 39 respondents, and partially reimbursed in 3 centres (7.7%). Eleven out of 20 centres (55%) reported acceptable patients' compliance (WCD worn for >90% of time). The most common indications for WCD (8 out of 10 centres; 80%) were covering the period until re-implantation of ICD explanted due to infection, in patients with left ventricular impairment due to myocarditis or recent myocardial infarction and those awaiting heart transplantation. Patient life expectancy of <12 months and poor compliance were the most commonly reported contraindications for WCD (24 of 46 centres, 52.2%). The major problems encountered by physicians managing patients with WCD were costs (8 of 18 centres, 44.4%), non-compliance, and incorrect use of WCD. Four of 17 centres (23.5%) reported inappropriate WCD activations in <5% of patients. The first shock success rate in terminating ventricular arrhythmias was 95-100% in 6 of 15 centres (40%), 85-95% in 4 (26.7%), 75-85% in 2 (13.3%), and <75% in 3 centres (20%). The survey has shown that the use of WCD in Europe is still restricted and depends on reimbursement. Patients' compliance remains low. Heterogeneity of indications for WCD among centres underscores the need for further research and a better definition of indications for WCD in specific patient groups.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/euw003 | DOI Listing |
Pharmacoecon Open
January 2025
Optimax Access Ltd, Kenneth Dibben House, Enterprise Rd, Chilworth, Southampton University Science Park, Southampton, UK.
Background: Patients with a left ventricular ejection fraction ≤ 35% are at increased risk of sudden cardiac death (SCD) within the first months after a myocardial infarction (MI). The wearable cardioverter defibrillator (WCD) is an established, safe and effective solution which can protect patients from SCD during the first months after an MI, when the risk of SCD is at its peak. This study aimed to evaluate the cost-effectiveness of WCD combined with guideline-directed medical therapy (GDMT) compared to GDMT alone, after MI in the English National Health Service (NHS).
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany.
The wearable cardioverter defibrillator (WCD) has emerged as a valuable tool used for temporary protection from sudden cardiac death. However, since the WCD uses surface electrodes to detect arrhythmias, it is susceptible to inappropriate detection. Although shock conversion rates for the WCD are reported to be high for detected events, its efficacy in clinical practice tends to be degraded by patient noncompliance.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Invasive Cardiology, Medical University of Białystok, 15-089 Białystok, Poland.
Sudden cardiac death (SCD) remains a major global health concern and represents one of the most common causes of mortality due to cardiovascular diseases. The wearable cardioverter-defibrillator (WCD) is an innovative, non-invasive medical device designed to provide continuous heart monitoring and immediate defibrillation in patients at risk for SCD. The study aimed to assess the efficacy of WCD usage in patients awaiting decision on therapy with implantable cardioverter-defibrillators (ICDs).
View Article and Find Full Text PDFGalen Med J
September 2024
Lorestan Heart Center (Madani Hospital), Lorestan University of Medical Sciences, Khorram-Abad, Lorestan, Iran.
Background: Heart failure (HF) is a chronic and progressive condition that its management presents significant challenges in both clinical settings and patient self-care. Recent advances in wearable technology offer promising solutions to these challenges by enabling continuous monitoring, early detection of clinical deterioration, and personalized care. This review aims to critically evaluate the impact of wearable technology on HF management Materials and Methods: This narrative systematic review was conducted across multiple databases, including PubMed, Web of Science, and the Cochrane Library, to identify relevant studies published between 2010 and 2024.
View Article and Find Full Text PDFEur Heart J
November 2024
Department of Cardiology, CHRU-Nancy, Université de Lorraine, Nancy, 1 rue du Morvan, 54500 Vandoeuvre-lès-Nancy, France.
Background And Aims: Prophylactic implantable cardioverter-defibrillators (ICDs) are not recommended until left ventricular ejection fraction (LVEF) has been reassessed 40 to 90 days after an acute myocardial infarction. In the current therapeutic era, the prognosis of sustained ventricular arrhythmias (VAs) occurring during this early post-infarction phase (i.e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!