Background: Hyperthyroidism is common in older cats, which necessitates frequent screening of serum total thyroxine (TT4) concentrations. Fast, cheap, and reliable methods to measure TT4 in cats are needed.

Objectives: The purpose of the study was the validation of a human TT4 enzyme immunoassay (EIA) for use with feline serum, and derivation of a TT4 reference interval (RI) for cats aged 9 years and older.

Methods: Assay precision, reproducibility, and linearity were evaluated. Interference by hemolysis was also assessed. Method comparison studies between the human EIA and a previously validated radioimmunoassay (RIA) and chemiluminescent-enzyme immunoassay (CEIA) were performed. Healthy cats (> 9 years) were recruited from 3 UK first opinion practices.

Results: The human TT4 EIA demonstrated good precision and reproducibility, and adequate linearity. Hemolysis did not significantly alter measured TT4 concentrations until HGB > 8 g/L. Method comparison revealed proportional and constant errors between EIA and RIA/CEIA. The TT4 RI for cats (> 9 years) was calculated as 7.1-45.1 nmol/L (n = 49).

Conclusions: The human TT4 EIA was successfully validated for use with feline serum and offers a rapid, cheap, and reliable method for determination of serum TT4 concentrations in cats.

Download full-text PDF

Source
http://dx.doi.org/10.1111/vcp.12324DOI Listing

Publication Analysis

Top Keywords

tt4 concentrations
12
human tt4
12
tt4
9
enzyme immunoassay
8
serum total
8
total thyroxine
8
cheap reliable
8
tt4 cats
8
feline serum
8
precision reproducibility
8

Similar Publications

Serum iodine concentration in pregnant women and its association with thyroid function.

J Trace Elem Med Biol

January 2025

Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, China; Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Reproductive Endocrinology, Women's Hospital, Zhejiang University School of Medicine, Zhejiang, China. Electronic address:

Objective: This study aims to investigate the association of serum iodine concentration (SIC) with thyroid function-associated parameters in pregnant women in mild iodine deficient area, and explore its potential to predict individual iodine nutrition status in pregnant women.

Methods: A total of 741 pregnant women undergoing prenatal examinations in their second trimester at the Women's Hospital, Zhejiang University School of Medicine, from March 2021 to May 2022 were finally recruited into the study. Venous blood and morning urine were collected.

View Article and Find Full Text PDF

Association of diethylhexyl phthalate exposure with serum thyroid hormone levels: a systematic review and meta-analysis.

Am J Transl Res

December 2024

Department of Genetics and Endocrinology, Chengdu Women's and Children's Center Hospital, School of Medicine, University of Electronic Science and Technology of China Chengdu, Sichuan, China.

Objective: Evidence suggests that diethylhexyl phthalate (DEHP) may disrupt thyroid hormone homeostasis by targeting multiple components of the hypothalamic-pituitary-thyroid (HPT) axis, potentially harming human health. However, the relationship between DEHP exposure and thyroid function remains debated. We performed a meta-analysis to clarify the association between DEHP exposure and thyroid function.

View Article and Find Full Text PDF

Background: Perchlorate, nitrate, and thiocyanate are well-known sodium/iodide symporter (NIS) inhibitors that disturb iodide uptake at the thyroid, affecting thyroid function. However, the associations between NIS inhibitor exposure and thyroid function are not well summarized in humans.

Objective: We aimed to summarize associations between NIS inhibitor exposure and thyroid function markers and to identify key information gaps for future studies.

View Article and Find Full Text PDF

Evaluation of a point-of-care test for quantitative determination of total thyroxine in feline serum.

J Feline Med Surg

January 2025

Department of Veterinary Medicine and Animal Sciences (DIVAS), University of Milan, Lodi (LO), Italy.

Objectives: Total thyroxine (TT4) evaluation is the most commonly used first-line test for the diagnosis and monitoring of cats with hyperthyroidism. Vcheck T4 is a point-of-care immunoassay that measures TT4 using a Vcheck V200 analyser. This study aimed to evaluate the analytic performance of the Vcheck T4 assay in feline sera and the agreement in the classification of normal, high and low TT4 concentrations of Vcheck T4 with those measured by an enzyme immunoassay (EIA).

View Article and Find Full Text PDF

Objectives: The aim of this study was to describe signalment, clinicopathological findings, management practices and the occurrence of comorbidities in feline diabetes mellitus (DM) in Germany.

Methods: This was a cross-sectional study using questionnaires and laboratory submissions to a commercial laboratory, Antech Lab Germany, between May 2021 and July 2022. Inclusion criteria were diagnosis of DM by the attending veterinarian and submission of a completed questionnaire besides blood samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!