Recently introduced tibial intramedullary nails allow a number of distal screws to be used to reduce the incidence of malalignment and loss of fixation of distal metaphyseal fractures. However, the number of screws and the type of screw configuration to be used remains obscure. This biomechanical study was performed to address this question. Thirty-six Expert tibial nails (Synthes, Oberdorf, Switzerland) were introduced in composite bone models. The models were divided into 4 groups with different distal locking configurations ranging from 2 to 4 screws. A 7-mm gap osteotomy was performed 72 mm from the tibial plafond to simulate a 42-C3 unstable distal tibial fracture. Each group was divided in 3 subgroups and underwent nondestructive biomechanical testing in axial compression, coronal bending, and axial torsion. The passive construct stiffness was measured and statistically analyzed with one-way analysis of variance. Although some differences were noted between the stiffness of each group, these were not statistically significant in compression (P=.105), bending (P=.801), external rotation (P=.246), and internal rotation (P=.370). This in vitro study showed that, when using the Expert tibial nail for unstable distal tibial fractures, the classic configuration of 2 parallel distal screws could provide the necessary stability under partial weight-bearing conditions.

Download full-text PDF

Source
http://dx.doi.org/10.3928/01477447-20160129-02DOI Listing

Publication Analysis

Top Keywords

distal locking
8
tibial fractures
8
distal screws
8
expert tibial
8
unstable distal
8
distal tibial
8
distal
7
tibial
7
screws
5
locking screws
4

Similar Publications

Distal augmentation in unstable distal clavicle fractures: a retrospective cohort study of 101 cases.

Arch Orthop Trauma Surg

January 2025

The Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 123, Ta Pei Road, Niao Sung Dist, Kaohsiung, Taiwan.

Introduction: The optimal management strategy for unstable distal clavicular fractures remains controversial. Recent studies on plate techniques have reported good-to-excellent outcomes with no serious complications. The questions are that: (1) Does the use of wire augmentation with locking plate in distal part (distal wire augmentation) reduce radiographic loss of reduction (RLOR) and get earlier bony union in distal clavicular fractures? (2) Which fixation methods are associated with a higher incidence of acromioclavicular (AC) joints arthritis or subluxation? We collected and analyzed clinical studies on different plate fixation methods for unstable fractures to identify the best surgical modality.

View Article and Find Full Text PDF

Background: Isolated distal fibula fractures (DFF) are usually treated with open reduction and internal fixation (ORIF) and non-weight-bearing protocols. The study assessed the outcomes of immediate weight-bearing on DFF healing and stability after lateral locking plating.

Materials And Methods: For this study, 49 patients affected by isolated DFF were enrolled.

View Article and Find Full Text PDF

Purpose Of Review: Numerous scope-related innovations have taken place in the field of endourology. The presented analytical review is aimed at studying the technical innovations of the single-use digital flexible ureteroscopes. In November 2024, a comprehensive search was done for information on latest disposable flexible digital ureteroscopes, as well as their various unique characteristics.

View Article and Find Full Text PDF

Distal fibula fractures involving the ankle are one of the most common fractures, often requiring open reduction and internal fixation with plates and screws. The increased incidence of potential wound complications arising from open reduction methods led to a rejuvenated interest in the application of minimally invasive methods like intramedullary nailing of the fibula in the management of ankle fractures and isolated distal fibular fractures. A literature search was performed using Medline, Cochrane, and Embase from 1993 to 2023.

View Article and Find Full Text PDF

Background: Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates/screws. We introduced our own surgical approach and reported the clinical/radiographic outcomes via retrospective case series.