AI Article Synopsis

Article Abstract

Purpose: To establish an optical section-assisted in vivo rabbit model for capsular bend and posterior capsule opacification (PCO) investigation.

Methods: A total of 10 rabbits underwent phacoemulsification surgery and intraocular lens (IOL) implantation. On the basis of the relationship between the anterior capsule and IOL, the rabbits were divided into complete overlap and incomplete overlap groups, in which six and four rabbits were included, respectively. The capsular bend optical sections were assessed using ultra-long scan depth optical coherence tomography (UL-OCT), and posterior capsule opacification was evaluated with slit lamp on postoperative day 3, 7, 14, and 28. In addition, histopathological section was used to verify the accuracy of capsular bend type captured by OCT in three rabbits.

Results: Based on the special animal model, six capsular bend types were observed, namely, anterior (A), middle (M), posterior (P), detachment (D), funnel (Fun) and furcate adhesion (Fur). On day 3, capsular bend began to form. On 14 days, the capsular bends were comprised of A, M and D types, which were almost maintained until day 28. Histopathological section findings were consistent with optical sectioning results. In the incomplete and complete groups, the earliest PCO within the optical zone were on day 7 and 28, respectively. The incomplete group exhibited higher incidence and faster PCO on day 7 (p = 0.038) and 14 (p = 0.002).

Conclusions: This animal model not only mimics capsular bend evolution and PCO processes but also produces OCT optical section images equivalent to and more repeatable than histopathology, thereby providing a promising method for the further investigations of PCO.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4739694PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0148553PLOS

Publication Analysis

Top Keywords

capsular bend
28
model capsular
12
posterior capsule
12
capsule opacification
12
optical section-assisted
8
section-assisted vivo
8
vivo rabbit
8
rabbit model
8
capsular
8
bend posterior
8

Similar Publications

Purpose: To observe and explore the correlation between visual outcomes and intraocular lens (IOL) stability after tri-focal IOL implantation in eyes with high myopia.

Methods: Patients with highly myopic cataract (axial length > 26 mm) were enrolled in this prospective study. Thirty-one eyes (31 patients) received implantation of a trifocal IOL (AcrySof IQ PanOptix TFNT00).

View Article and Find Full Text PDF

Purpose: To evaluate intraocular lens (IOL) rotational stability and capsular fusion process after cataract surgery with and without primary posterior continuous curvilinear capsulorrhexis (PPCCC).

Setting: Fujian Provincial Hospital, Fujian, China.

Design: Prospective, intraindividual, randomized clinical trial.

View Article and Find Full Text PDF

Background And Objective: Endoscopic endonasal approaches to treat cavernous sinus lesions require detailed knowledge of the origin, course, and anatomic variations of the branches of the cavernous internal carotid artery (cICA) because inadvertent avulsion can cause intraoperative ICA injury. We aim to study the origin and course of the branches of the cICA from an endoscopic endonasal perspective and relate these branches to surgically relevant anatomic references.

Methods: Sixty sides of 30 formalin-fixed specimens were dissected to identify the origin and course of cICA branches, including the inferolateral trunk (ILT), the meningohypophyseal trunk (MHT), anterior and inferior McConnell's capsular arteries (MCAs), and the superolateral trunk (SLT).

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess how a capsular tension ring (CTR) impacts the stability of the intraocular lens (IOL) after cataract surgery in patients with long axial lengths.
  • The research included 43 patients and measured various indicators, such as postoperative aqueous depth and lens position, using advanced imaging over three months.
  • Results showed that CTR significantly improved IOL stability and reduced decentration post-surgery compared to those who didn't receive the CTR, while not impacting refractive outcomes.
View Article and Find Full Text PDF

Introduction: The aim of this work is to investigate the dynamic changes of capsular-intraocular lens (IOL) adhesion in plate-haptic hydrophilic and loop-haptic hydrophobic eyes.

Methods: Cataract eyes that met the inclusion criteria were randomly assigned to receive implantation of a plate-haptic hydrophilic or loop-haptic IOL. The anterior capsular adhesion, posterior capsular adhesion, and the configurations of the capsular bend were evaluated using swept-source optical coherence tomography at 1 day, 1 week, 1 month, and 3 months postoperatively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!