Aim: To determine whether observations were reproducible among investigators.
Methods: From March 2013 through June 2014, 18-85-year-old diagnostic and 50-70-year-old screening patients were enrolled at each center to on-demand sedation colonoscopy with water exchange (WE), water immersion (WI) and insufflation with air or CO2 for insertion and withdrawal [air or carbon dioxide (AICD)]. Data were aggregated for analysis.
Primary Outcome: Variations in real-time maximum insertion pain (0 = none, 1-2 = discomfort, 10 = worst).
Results: One thousand and ninety-one cases analyzed: WE (n = 371); WI (n = 338); AICD (n = 382). Demographics and indications were comparable. The WE group had the lowest real-time maximum insertion pain score, mean (95%CI): WE 2.8 (2.6-3.0), WI 3.8 (3.5-4.1) and AICD 4.4 (4.1-4.7), P < 0.0005. Ninety percent of the colonoscopists were able to use water exchange to significantly decrease maximum insertion pain scores. One investigator had high insertion pain in all groups, nonetheless WE achieved the lowest real-time maximum insertion pain score. WE had the highest proportions of patients with painless unsedated colonoscopy (vs WI, P = 0.013; vs AICD, P < 0.0005); unsedated colonoscopy with only minor discomfort (vs AICD, P < 0.0005), and completion without sedation (vs AICD, P < 0.0005).
Conclusion: Aggregate data confirm superiority of WE in lowering colonoscopy real-time maximum insertion pain and need for sedation. Ninety percent of investigators were able to use water exchange to significantly decrease maximum insertion pain scores. Our results suggest that the technique deserves consideration in a broader scale.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4724028 | PMC |
http://dx.doi.org/10.4253/wjge.v8.i2.113 | DOI Listing |
Urolithiasis
January 2025
Urology Department, Benha University, Benha, Qalubia, Egypt.
Studies in literature discussed the drawbacks of the ureteral access sheath use in flexible ureteroscopy and in the same time mentioned the benefits of ureteral access sheath in decreasing the incidence of urosepsis and better stone free rate. In the current study we aim to compare between percutaneous nephrostomy tube (PCN) insertion before flexible ureteroscopy and conventional ureteral access sheath (UAS) flexible ureteroscopy in terms of safety, efficacy and perioperative outcomes. In all, 100 Patients aged 20 to 67 years with upper ureteric stones and mild hydronephrosis or renal pelvic stones less than 20 mm with mild hydronephrosis were randomized into 2 groups; patients undergoing PCN insertion before flexible ureteroscopy, and patients undergoing the conventional UAS flexible ureteroscopy.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Korea.
Background: Monitoring core temperature is important for patients under anesthesia. Esophageal and pulmonary artery blood temperatures can be used for measuring core temperature during general anesthesia. However, these methods pose challenges, especially when the placement of an esophageal thermometer and pulmonary artery catheter (PAC) is either impractical or not the preferred approach.
View Article and Find Full Text PDFInt J Surg Oncol
January 2025
Department of Surgical Oncology, Dr Bhubaneswar Borooah Cancer Institute, Guwahati, India.
Esophageal cancer is the sixth most common cancer in India with a incidence of around 4.5%. Dysphagia is the primary manifestation of advanced esophageal cancer in 80%-90% of patients.
View Article and Find Full Text PDFFront Med (Lausanne)
December 2024
Department of Anaesthesiology and Intensive Therapy, Medical University of Lodz, Łódź, Poland.
Background: The Laryngeal Mask Airway Vision Mask (LMA VM) is a supraglottic airway device (SAD) with a vision guidance system. The ideal head and neck position for direct laryngoscopy is known, but the ideal position for placing a LMA is not. The objective of this study is to evaluate and compare the optimal position for placement of a video laryngeal mask airway.
View Article and Find Full Text PDFCureus
November 2024
Pain Management, Singapore General Hospital, Singapore, SGP.
Subglottic stenosis poses a rare but life-threatening risk for difficult tracheal intubation. Here, we report a unique case of undiagnosed subglottic stenosis discovered during emergency intubation of an 80-year-old woman with type 2 respiratory failure from infective exacerbation of asthma. A small calibre size 5.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!