A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ratiometric optical fiber sensor for dual sensing of copper ion and dissolved oxygen. | LitMetric

This paper develops a new ratiometric optical dual sensor for Cu2+ ions and dissolved oxygen (DO) incorporating a sol-gel matrix doped with palladium tetrakis pentafluorophenyl porphine as the oxygen-sensitive material, CdSe quantum dots as the Cu2+ ion-sensing material, and 7-amino-4-trifluoromethyl coumarin as the Cu2+ /DO practically independent fluorescent dye. The feasibility of coating an optical fiber with the sensing film to fabricate a ratiometric optical fiber dual sensor is investigated. Using an LED with a central wavelength of 405 nm as an excitation source, it is shown that the emission wavelengths of the Cu2+ ion-sensitive, DO-sensitive dye and the reference dye have no spectral overlap and therefore permit Cu2+ ion and DO concentration to be measured using a ratiometric-based method. The ratiometric optical fiber dual sensor has been tested with regard to monitoring different Cu2+ ion (0-10 μM) and DO concentrations (0-38 mg/L). The results show that the luminescence properties of the Cu2+ ion sensor are independent of the presence of the oxygen sensor and have a uniquely good linear response in the 0-10 μM range. The proposed ratiometric sensing approach presented in this study has the advantage of suppressing spurious fluctuations in the intensity of the excitation source.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.54.010659DOI Listing

Publication Analysis

Top Keywords

ratiometric optical
16
optical fiber
16
dual sensor
12
cu2+ ion
12
dissolved oxygen
8
fiber dual
8
excitation source
8
0-10 μm
8
cu2+
7
sensor
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!