A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quasi-distributed birefringence dispersion measurement for polarization maintain device with high accuracy based on white light interferometry. | LitMetric

A white light temporal interferometric technique for measurement of the quasi-distributed birefringence dispersion (BD) in a polarization maintain (PM) device with high accuracy based on weighted least square (WLS) method is presented. It is verified theoretically and experimentally that the accuracy of WLS method and the conventional ordinary least square (OLS) method both are proportional to the signal-to-noise ratio (SNR) of interferogram, whereas the WLS method holds a higher scaling factor because it is more suitable for heteroscedastic model that has unequal error variance. The experiment results show a repeatability of ~4.6 × 10(-5) ps/nm @ 1550 nm with WLS method for 100 sets of data, and ~4.3 × 10(-4) ps/nm with OLS method, for an interferogram with SNR of 30 dB. Besides, WLS method without iterative operation is carried out by using power spectrum of interferogram as weight value. The feasibility of this technique is demonstrated by distinguishing the quasi-distributed BD of every part for a packaged Y-waveguide with two 1m-long PM pigtails.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.24.001587DOI Listing

Publication Analysis

Top Keywords

wls method
20
quasi-distributed birefringence
8
birefringence dispersion
8
polarization maintain
8
maintain device
8
device high
8
high accuracy
8
accuracy based
8
white light
8
ols method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!