AI Article Synopsis

  • The CIEDE2000 and CIE94 equations are key for calculating color differences, based on visual data from psychophysical tests that compare color samples.
  • The current study shows that changing reference pairs in color difference calculations can significantly affect the results, particularly with metallic paint samples of red and yellow-green.
  • Findings indicate that color perception varies among observers, with differences in tolerances for lightness and rotations in color difference measurements, likely influenced by the metallic texture of the samples.

Article Abstract

For calculating color differences, the CIEDE2000 and CIE94 equations are widely used and recommended. These equations were derived more than a decade ago, based for a large part on the RIT-Dupont set of visual data. This data was collected from a series of psychophysical tests that use the method of constant stimuli. In this method, observers need to compare the color difference within a sample pair to that between a reference pair. In the current investigation, we show that the color difference equation significantly changes if reference pairs are chosen in the underlying visual experiments that differ from what was used when creating the RIT-Dupont dataset. The investigation is done using metallic paint samples representing two color centers, red and yellow-green. We show that the reproducibility differs for three different reference pairs, and that for modeling the visual data for the yellow-green color center, extra model terms are required as compared to the CIEDE2000 equation. Our results suggest that observers differ in their ability to mentally convert a color difference recognized in a sample pair into an equivalent color difference along the color difference direction represented by the reference pair. We also find that in these tests the tolerance to lightness differences is widened by a factor of 1.3 to 1.6, and that for the red color center the tolerance ellipsoid is rotated by 30° as compared to the CIEDE2000 equation. The latter observations are possibly due to the metallic texture in the samples used for the current experiment.

Download full-text PDF

Source
http://dx.doi.org/10.1364/JOSAA.32.002373DOI Listing

Publication Analysis

Top Keywords

color difference
24
reference pairs
12
color
10
constant stimuli
8
visual data
8
sample pair
8
reference pair
8
color center
8
compared ciede2000
8
ciede2000 equation
8

Similar Publications

'Lanjingling' [China National Plant Variety Protection (CNPVP) 20200389] is the first new nationally registered cultivar of blue honeysuckle (Lonicera caerulea L.) developed by the Northeast Agricultural University for the fresh-fruit market (Zhu et al. 2022).

View Article and Find Full Text PDF

Objective: Elevated intracranial pressure (ICP), a common complication in traumatic brain injuries (TBI), can lead to optic nerve sheath diameter (ONSD) enlargement and flow spectrum changes from the internal carotid artery (ICA) to middle cerebral artery (MCA). This study will investigate the use of Cervical-Cerebral Arterial Ultrasound (CCAU) for non-invasive ICP assessment and evaluating the related indices' clinical utility in TBI patients with decompressive craniotomy (DC).

Methods: ONSD and flow spectrum changes were measured within 24 h after DC in 106 patients via ultrasonic ONSD measurement and CCAU, simultaneously.

View Article and Find Full Text PDF

For paediatric patients suffering from neurofibromatosis, Selumetinib (SEL) is the only approved drug. Here an original ecofriendly and high pace method is introduced using 96- microwell spectrophotometric assay (MW-SPA) to measure SEL content in bulk and commercial pharmaceutical formulation (Koselugo capsules). This assay was relied on in-microwell formation of a coloured charge transfer complex (CTC) upon interaction of SEL with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ).

View Article and Find Full Text PDF

Background: In recent years, there have been suggestions for new restorative strategies that aim to effectively utilize modern adhesive technologies and protect the remaining intact tooth structure. This study was conducted to evaluate the clinical performance of fiber reinforced resin composites in restoring Class II MOD cavities over 18 months.

Methods: Forty-five participants with class II MOD cavities were randomly enrolled.

View Article and Find Full Text PDF

A Retrospective Study of Pediatric Allergic Contact Dermatitis from 2017-2022.

Dermatol Ther (Heidelb)

January 2025

Burkhart Pediatric and Adolescent Dermatology, Cary, NC, USA.

Objectives: Allergic contact dermatitis occurs frequently in children. The proportion of children of color in the US is increasing, and racial and ethnic minority representation is important in pediatric allergic contact dermatitis research. The objectives of our study were to identify differences in age, sex, race and ethnicity among pediatric patch tests obtained from 2017 to 2022.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!