Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Plasma alkylresorcinols are increasingly analyzed in cohort studies to improve estimates of whole grain intake and their relationship with disease incidence. Current methods require large volumes of solvent (>10 ml/sample) and have relatively low daily sample throughput. We tested five different supported extraction methods for extracting alkylresorcinols from plasma and improved a normal-phase liquid chromatography coupled to a tandem mass spectrometer method to reduce sample analysis time. The method was validated and compared with gas chromatography-mass spectrometry analysis. Sample preparation with HybridSPE supported extraction was most effective for alkylresorcinol extraction, with recoveries of 77-82% from 100 μl of plasma. The use of 96-well plates allowed extraction of 160 samples per day. Using a 5-cm NH2 column and heptane reduced run times to 3 min. The new method had a limit of detection and limit of quantification equivalent to 1.1-1.8 nmol/L and 3.5-6.1 nmol/L plasma, respectively, for the different alkylresorcinol homologues. Accuracy was 93-105%, and intra- and inter-batch precision values were 4-18% across different plasma concentrations. This method makes it possible to quantify plasma alkylresorcinols in 100 μl of plasma at a rate of at least 160 samples per day without the need for large volumes of organic solvents.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ab.2015.12.023 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!