Background: Approximately 18% of the patients are dissatisfied with the result of total knee replacement. However, the relation between dissatisfaction and prosthetic alignment has not been investigated before.
Methods: We retrospectively analysed prospectively gathered data of all patients who had a primary TKR, preoperative and one-year postoperative Oxford Knee Scores (OKS) and postoperative computed tomography (CT). The CT protocol measures hip-knee-ankle (HKA) angle, and coronal, sagittal and axial component alignment. Satisfaction was defined using a five-item Likert scale. We dichotomised dissatisfaction by combining '(very) dissatisfied' and 'neutral/not sure'. Associations with dissatisfaction and change in OKS were calculated using multivariable logistic and linear regression models.
Results: 230 TKRs were implanted in 105 men and 106 women. At one year, 12% were (very) dissatisfied and 10% neutral. Coronal alignment of the femoral component was 0.5 degrees more accurate in patients who were satisfied at one year. The other alignment measurements were not different between satisfied and dissatisfied patients. All radiographic measurements had a P-value>0.10 on univariate analyses. At one year, dissatisfaction was associated with the three-months OKS. Change in OKS was associated with three-months OKS, preoperative physical SF-12, preoperative pain and cruciate retaining design.
Discussion: Neither mechanical axis, nor component alignment, is associated with dissatisfaction at one year following TKR. Patients get the best outcome when pain reduction and function improvement are optimal during the first three months and when the indication to embark on surgery is based on physical limitations rather than on a high pain score.
Level Of Evidence: 2.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.knee.2015.12.007 | DOI Listing |
Knee Surg Sports Traumatol Arthrosc
December 2024
Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia Dello Sport, UOC Ortopedia e Traumatologia, Brescia, Italy.
Purpose: The application of robotics in revision arthroplasty particularly from unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA), is underexplored. The purpose of this study is to describe the surgical technique of an imageless robotic system used in the revision of UKA to TKA and to evaluate short- to mid-term outcomes.
Methods: This prospective study includes 35 patients treated from May 2020 to July 2023.
Ann Vasc Surg
December 2024
Departamento de Cirugía Vascular y Endovascular, Escuela de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile. Electronic address:
Background: Visceral artery aneurysms (VAAs) are a relatively uncommon phenomenon, occurring all types of VAA at an incidence of 0.01% to 0.2%.
View Article and Find Full Text PDFBiosensors (Basel)
December 2024
Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China.
Ankle-foot orthoses (AFOs) have been commonly prescribed for stroke survivors with foot drop, but their impact on the contractions of paretic tibialis anterior (TA) and medial gastrocnemius (MG) has remained inconclusive. This study thus investigated the effect of AFOs on these muscle contractions in stroke survivors. The contractions of paretic TA and MG muscles were assessed in twenty stroke patients and compared between walking with and without AFOs, using a novel wearable dynamic ultrasound imaging and sensing system.
View Article and Find Full Text PDFDent J (Basel)
December 2024
Department of Implant-Prosthetic Therapy, Faculty of Dentistry, "Carol Davila" University of Medicine and Pharmacy, 050474 Bucharest, Romania.
Full-arch zirconia restorations on implants have gained popularity due to zirconia's strength and aesthetics, yet they are still associated with challenges like structural fractures, peri-implant complications, and design misfits. Advances in CAD/CAM and digital workflows offer potential improvements, but a technique that consistently addresses these issues in fixed, full-arch, implant-supported prostheses is needed. This novel technique integrates a facially and prosthetically driven treatment approach, which is divided into three phases: data acquisition, restoration design, and manufacturing/delivery.
View Article and Find Full Text PDFOrthod Craniofac Res
December 2024
Department of Orthodontics and Dentofacial Orthopedics, Dental School/Medical Faculty, University of Bern, Bern, Switzerland.
The primary objective was to systematically assess the prevalence, incidence and risk factors of WSLs with orthodontic treatment. The secondary objective was to compare the prevalence of WSLs between conventional fixed appliances (CFA) and other appliances, as well as with no treatment. PubMed, Scopus, Web of Science, LILACs, Virtual Health Library and Cochrane CENTRAL were searched.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!