Ann Pediatr Cardiol
December 2024
Department of Cardiothoracic Surgery, Apollo Children's Hospital, Chennai, Tamil Nadu, India.
Background: Branch pulmonary artery (PA) stenosis must be addressed early to prevent right ventricular scarring and establish lung blood flow. Balloon-mounted stents are more useful in managing right ventricular outflow tract (RVOT) obstruction and PA stenosis.
Materials And Methods: We studied the clinical and angiographic data of children with congenital heart disease who underwent stenting for RVOT obstruction and branch PA stenosis using the Formula stent (Cook Medical, Limerick, Ireland) between 2018 and 2024 in a tertiary pediatric cardiac center in southern India.
J Biophotonics
January 2025
Department of Electrical Engineering, Columbia University, New York, New York, USA.
Epicardial catheter ablation is necessary to address ventricular tachycardia targets located far from the endocardium, but epicardial adipose tissue and coronary blood vessels can complicate ablation. We demonstrate that catheter-based near-infrared spectroscopy (NIRS) can identify these obstacles to guide ablation. Eighteen human ventricles were mapped ex vivo using NIRS catheters with optical source-detector separations (SDSs) of 0.
View Article and Find Full Text PDFJACC Clin Electrophysiol
January 2025
Section of Cardiac Pacing and Electrophysiology, Division of Cardiology, Cleveland Clinic, Cleveland, Ohio, USA.
Background: In patients with mechanical aortic and mitral valves requiring catheter ablation of ventricular tachycardia (VT), a technique for access from the right atrium (RA) to the left ventricle (LV) via puncture of the inferoseptal process of the LV was previously described in a single-center series.
Objectives: This study sought to report the multicenter experience of VT ablation using this novel LV access approach.
Methods: We assembled a multicenter registry of patients with double mechanical valves who underwent VT ablation with RA-to-LV access.
J Arrhythm
February 2025
Department of Cardiology Saitama Medical University, International Medical Center Hidaka Japan.
Background: A novel contact force (CF) sensing catheter with a mesh-shaped irrigation tip (TactiFlexTM SE, Abbott), is expected to provide safe and effective radiofrequency ablation. Our previous study revealed that the TactiFlex catheter needs a higher power for pulmonary vein isolation (PVI) due to the long tip length. This study aimed to examine the feasibility and safety of a 50 W ablation with the TactiFlex for PVI of atrial fibrillation (AF).
View Article and Find Full Text PDFBackground: Few clinical studies of atrial fibrillation (AF) have focused on Asian patients; data are lacking on current mapping and ablation strategies in the Asia Pacific region (APAC).
Objective: The HD Mapping Observational Study (NCT04022954) was designed to characterize electroanatomic mapping (EAM) with market-released high-density mapping (HDM) catheters in subjects with AF in APAC.
Methods: Subjects undergoing HDM and indicated for radiofrequency ablation (RFA) to treat AF were prospectively enrolled in APAC.