A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reduction of inappropriate anti-tachycardia pacing therapies and shocks by a novel suite of detection algorithms in heart failure patients with cardiac resynchronization therapy defibrillators: a historical comparison of a prospective database. | LitMetric

Aims: Implantable cardioverter defibrillators improve survival of patients at risk for ventricular arrhythmias, but inappropriate shocks occur in up to 30% of patients and have been associated with worse quality of life and prognosis. In heart failure patients with cardiac resynchronization therapy defibrillators (CRT-Ds), we evaluated whether a new generation of detection and discrimination algorithms reduces inappropriate shocks.

Methods And Results: We analysed 1983 Medtronic CRT-D patients (80% male, 67 ± 10 years), 1368 with standard devices (Control CRT-D) and 615 with new generation devices (New CRT-D). Expert electrophysiologists reviewed and classified the electrograms of all device-detected ventricular tachycardia/fibrillation episodes. Total follow-up was 3751 patients-years. Incidence of inappropriate shocks at 1 year was 2.8% [95% confidence interval (CI) = 2.0-3.5] in Control CRT-D and 0.9% (CI = 0.4-2.2) in New CRT-D (hazard ratio = 0.37, CI = 0.21-0.66, P < 0.001). In New CRT-D, inappropriate shocks were reduced by 77% [incidence rate ratio (IRR) = 0.23, CI = 0.16-0.35, P < 0.001] and inappropriate anti-tachycardia pacing by 81% (IRR = 0.19, CI = 0.11-0.335, P < 0.001). Annual rate per 100 patient-years for appropriate VF detections was 3.0 (CI = 2.1-4.2) in New CRT-D and 3.2 (CI = 2.1-5.0) in Control CRT-D (P = 0.68), for syncope was 0.4 (CI = 0.2-0.9) in New CRT-D and 0.7 (CI = 0.5-1.0) in Control CRT-D (P = 0.266), and for death was 1.0 (CI = 0.6-1.6) in New CRT-D and 3.5 (CI = 3.0-4.1) in Control CRT-D (P < 0.001).

Conclusion: Detection and discrimination algorithms used in new generation CRT-D significantly reduced inappropriate shocks when compared with standard CRT-D. This result, with no compromise on VF sensitivity or risk of syncope, has important implications for patients' quality of life and prognosis.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euv420DOI Listing

Publication Analysis

Top Keywords

control crt-d
20
inappropriate shocks
16
crt-d
14
inappropriate anti-tachycardia
8
anti-tachycardia pacing
8
heart failure
8
failure patients
8
patients cardiac
8
cardiac resynchronization
8
resynchronization therapy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!