AI Article Synopsis

  • The study investigates whether valgus angulation develops during tibial lengthening using the lengthening over nail (LON) technique, contrasting it with the classic Ilizarov method, which is known to produce such deformation due to soft tissue forces.
  • It involved a retrospective analysis of 60 patients with a mean follow-up of 42 months, measuring changes in tibial angles before, during, and after the lengthening process to assess any valgus deviation.
  • Researchers also examined various demographic and surgical factors that might influence the occurrence of valgus deviation during the LON technique.

Article Abstract

Background: During tibial lengthening, the soft tissues of the posterolateral compartment produce distraction-resisting forces causing valgus angulation. Although this occurs with the classic Ilizarov method, whether a valgus deformity develops with the lengthening over nail (LON) technique is questioned, because the intramedullary nail is thought to resist deforming forces and adequately maintain alignment of the distracted bone.

Questions/purposes: The purposes of this study were to (1) determine the amount of valgus deviation during tibial lengthening with the LON technique; and (2) analyze the factors that may be associated with valgus deviation with the LON technique.

Methods: Between June 2009 and September 2013, we performed 346 tibial lengthenings using the LON technique, lengthening and then nail technique, or lengthening with an intramedullary lengthening device. Sixty patients (120 tibias) who underwent bilateral lower leg lengthening with the LON technique were enrolled in this retrospective study. To limit the number of variables, we analyzed only the right tibia in all patients (60 tibias). The mean followup was 42 months (range, 26-71 months). The mean age of the patients was 25 years (range, 18-40 years). There were 36 male and 24 female patients. The mean final length gain was 67 ± 9 mm. The mean time for distraction was 100 ± 25 days. The overall valgus deviation was assessed by measuring the change in the medial proximal tibial angle and mechanical femorotibial angle on radiographs obtained before and after surgery and after completion of lengthening. Several demographic, surgical, and distraction-related variables were considered possible factors to prevent valgus deviation: proximal fixation method; presence of a blocking screw; diameter and length of the intramedullary nail; degree of nail insertion; length of the nail in the distal segment after completion of distraction; final length gain; and patient's BMI. During the period studied, the blocking screw was to maintain the mechanical axis in patients who had neutral or valgus alignment preoperatively, or to prevent more valgus change in patients who underwent acute correction of varus deformity intraoperatively. Uni- and multivariate analyses were conducted.

Results: Valgus deviation occurred during the tibial LON. The medial proximal tibial angle increased from 86° (95% CI, 85°-86°) to 90° (95% CI, 89°-91°) (p < 0.001). The mechanical femorotibial angle changed from 2.2° varus (95% CI, 3°-1.4° varus) to 2.6° valgus (95% CI, 1.8°-3.4° valgus) (p < 0.001). Valgus deviation was evident in proximal and distal segments. In the multivariate regression model, use of a blocking screw was the only factor that was associated with decreased valgus deviation, and its effect size, although detectable, was small (-2.62; 95% CI, -4.65 to -0.59; p = 0.013).

Conclusions: We found that valgus deviation does occur during tibial lengthening using the LON technique, but that blocking screw placement may help to minimize the likelihood that severe valgus deviation will occur. Future prospective studies should be conducted to confirm this preliminary finding.

Level Of Evidence: Level III, therapeutic study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4814428PMC
http://dx.doi.org/10.1007/s11999-016-4712-8DOI Listing

Publication Analysis

Top Keywords

valgus deviation
40
lon technique
20
blocking screw
16
valgus
15
lengthening nail
12
tibial lengthening
12
lengthening lon
12
deviation
10
lengthening
10
tibial
8

Similar Publications

Background: This study aimed to compare the prevalence of hallux valgus interphalangeus (HVI) in juvenile-onset hallux valgus and adult-onset hallux valgus and to analyze the correlation between the hallux interphalangeal angle (HIA) and other radiographic parameters in juvenile-onset hallux valgus.

Methods: This retrospective study included 640 feet and 320 patients with hallux valgus (160 juvenile-onset and 160 adult-onset cases). Eight radiographic parameters were measured: HIA, hallux valgus angle, intermetatarsal angle, talonavicular coverage angle, anteroposterior talocalcaneal angle, lateral talocalcaneal angle, lateral talo-first metatarsal angle, and calcaneal pitch.

View Article and Find Full Text PDF

Comparison of the effects of orthoses on hallux valgus angle and plantar pressure in individuals with hallux valgus.

Prosthet Orthot Int

December 2024

Department of Orthosis and Prosthetics, School of Health Sciences, Istanbul Medipol University, Istanbul, Turkey.

Background: Hallux valgus (HV) is a condition characterized by the lateral deviation of the first phalanx and medial deviation of the first metatarsal, leading to subluxation of the first metatarsophalangeal joint. Various orthotic applications are employed in the treatment of HV deformity. This study aimed to compare the effects of a toe separator (TS) and dynamic orthosis (DO) on hallux valgus angle (HVA), plantar pressure (PP), and quality of life (QoL).

View Article and Find Full Text PDF

Assessment of the Radiographic Angular Parameters in the Coronal Plane of the Lower Limbs in Subjects without Knee Osteoarthritis in a Reference Hospital of the Brazilian Unified Health System.

Rev Bras Ortop (Sao Paulo)

December 2024

Centro de Atenção Especializada do Tratamento da Dismetria e Deformidades do Aparelho Locomotor, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil.

 The present study aims to demonstrate the radiological angular parameters of a sample of patients treated at our institution and to compare the radiological abnormalities with other classifications or parameters from the literature.  We evaluated a sample of patients submitted to panoramic radiographic examinations of the lower limbs. The inclusion criteria were: (1) Patients without knee osteoarthritis as assessed by an orthopedist.

View Article and Find Full Text PDF

Low rate of growth disturbance after posterior cruciate ligament reconstruction or repair in skeletally immature patients: a systematic review.

J ISAKOS

December 2024

Gelenkpunkt-Sports and Joint Surgery FIFA Medical Centre of Excellence, Innsbruck, Austria; Research Unit for Orthopaedic Sports Medicine and Injury Prevention (OSMI), Private University for Health Sciences Medical Informatics and Technology, Innsbruck, Austria.

Importance: The management of posterior cruciate ligament (PCL) injuries in children is complex and varies depending on the specific nature of the injury. Avulsions of the PCL can often be addressed with proximal or distal repair, while intra-substance tears and cases with persistent instability generally require more extensive reconstruction. Despite the prevalence of such cases, the literature is predominantly composed of case reports, indicating a lack of comprehensive research in this area.

View Article and Find Full Text PDF

Purpose: To compare different measurement techniques of the posterior tibial slope (PTS) on lateral radiographs with the actual in situ PTS and evaluate the effect of tibial malrotation and image section length.

Methods: Actual PTS was measured on eight fresh-frozen tibiae using a portable 6-axis measuring arm with an accuracy of ±0.01°.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!