Clinical Trial of Thermal Pulsation (LipiFlow) in Meibomian Gland Dysfunction With Preteatment Meibography.

Eye Contact Lens

Yong Loo Lin School of Medicine (Y.Z., L.T.), National University of Singapore, Singapore; Ocular Surface Research Group (A.V., S.Y., L.T.), Singapore Eye Research Institute; University of Alabama School of Medicine at UAB (D.M.R.), Birmingham, AL; School of Biomedical Engineering (R.U.A., J.H.T.), Ngee Ann Polytechnic, Singapore; Singapore National Eye Center (L.T.); and Duke-NUS Graduate Medical School (L.T.), Singapore.

Published: November 2016

Objectives: Thermal pulsation (LipiFlow) has been advocated for meibomian gland dysfunction (MGD) treatment and was found useful. We aimed to evaluate the efficacy and safety of thermal pulsation in Asian patients with different grades of meibomian gland loss.

Methods: A hospital-based interventional study comparing thermal pulsation to warm compresses for MGD treatment. Fifty patients were recruited from the dry eye clinic of a Singapore tertiary eye hospital. The ocular surface and symptom were evaluated before treatment, and one and three months after treatment. Twenty-five patients underwent thermal pulsation (single session), whereas 25 patients underwent warm compresses (twice daily) for 3 months. Meibomian gland loss was graded using infrared meibography, whereas function was graded using the number of glands with liquid secretion.

Results: The mean age (SD) of participants was 56.4 (11.4) years in the warm compress group and 55.6 (12.7) years in the thermal pulsation group. Seventy-six percent of the participants were female. Irritation symptom significantly improved over 3 months in both groups (P<0.01), whereas tear breakup time (TBUT) was modestly improved at 1 month in only the thermal pulsation group (P=0.048), without significant difference between both groups over the 3 months (P=0.88). There was also no significant difference in irritation symptom, TBUT, Schirmer test, and gland secretion variables between patients with different grades of gland loss or function at follow-ups.

Conclusions: A single session of thermal pulsation was similar in its efficacy and safety profile to 3 months of twice daily warm compresses in Asians. Treatment efficacy was not affected by pretreatment gland loss.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5098463PMC
http://dx.doi.org/10.1097/ICL.0000000000000228DOI Listing

Publication Analysis

Top Keywords

thermal pulsation
24
meibomian gland
16
pulsation lipiflow
8
gland dysfunction
8
mgd treatment
8
warm compresses
8
patients underwent
8
thermal
6
pulsation
6
clinical trial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!