Aims: To assess the serial changes of de novo coronary lesions treated with paclitaxel-coated balloon (PCB) using intravascular ultrasound virtual histology (IVUS-VH) and fractional flow reserve (FFR).

Method And Results: This prospective observational study enrolled 27 patients with coronary artery disease treated with PCB who underwent coronary angiography, IVUS-VH and FFR before, immediately after intervention and at 9 months. 28 de novo lesions were successfully treated with PCB. Angiographic late luminal loss was 0.02 ± 0.27 mm. Mean vessel and lumen areas showed increase at 9 months (12.0 ± 3.5 mm(2) to 13.2 ± 3.9 mm(2), p <0.001; and 5.4 ± 1.2 mm(2) to 6.5 ± 1.8 mm(2), p <0.001, respectively). Although mean plaque area was unchanged (6.6 ± 2.6 mm2 to 6.6 ± 2.4 mm(2), p = 0.269), percent atheroma volume decreased significantly (53.4 ± 7.9% to 49.5 ± 6.4%, p = 0.002). The proportion of plaque compositions including fibrous, fibrofatty, dense calcium and necrotic core by IVUS-VH was unchanged at 9 months. The FFR of the treated lesion was 0.71 ± 0.13 pre-procedure, 0.87 ± 0.06 post-procedure and 0.84 ± 0.06 at follow-up.

Conclusions: De novo coronary lesions treated with PCB showed persistent anatomical and physiological patency with plaque redistribution and vessel remodeling without chronic elastic recoil or plaque compositional change during follow-up.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4733051PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0147057PLOS

Publication Analysis

Top Keywords

paclitaxel-coated balloon
8
novo coronary
8
coronary lesions
8
ivus-vh ffr
8
lesions treated
8
treated pcb
8
anatomical physiological
4
physiological changes
4
changes paclitaxel-coated
4
balloon atherosclerotic
4

Similar Publications

Efficacy and Safety of Sirolimus-Coated Balloon Angioplasty in De Novo Lesions in Large Coronary Vessels: A Propensity Score-Matched Study.

Catheter Cardiovasc Interv

January 2025

Department of Cardio-Thoracic-Vascular Diseases, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.

Background: Evidence regarding drug-coated balloon (DCB)-only angioplasty in de novo lesions of large vessels is still limited and mainly focused on paclitaxel-coated balloon. We aimed to analyze the safety and efficacy of sirolimus-coated balloon (SCB)-only angioplasty in de novo lesions in large vessels compared to drug-eluting stent (DES).

Methods: In this retrospective, dual-center, case-control study, we enrolled all consecutive patients treated between January 2022 and January 2024 with SCB-only angioplasty in de novo lesion in large vessel (> 2.

View Article and Find Full Text PDF

Background: Drug-coated balloons present a potentially advantageous therapeutic approach for managing coronary in-stent restenosis (ISR). However, the comparative benefits of paclitaxel-coated balloons (PCBs) over uncoated balloons (UCBs) remain unclear.

Aims: We conducted a systematic review and meta-analysis to evaluate and compare the clinical outcomes of patients treated with PCBs and UCBs.

View Article and Find Full Text PDF

Introduction: Initial surgical revascularization has a recognized primary role in patients with critical limb-threatening ischemia with a high-quality great saphenous vein for conduit. However, approximately one-third of lower extremity vein grafts develop lesions threatening graft patency. Traditional treatments have limitations, highlighting the need for innovative solutions.

View Article and Find Full Text PDF

Paclitaxel can inhibit smooth muscle cell proliferation and migration, and reduce the risk of vascular restenosis after balloon dilation. Our study investigated the safety and efficacy of paclitaxel-coated balloon (PCB) treatment for diabetic subpatellar artery disease. In this study, 140 patients with diabetic subknee arterial disease treated in our hospital from January 2022 to December 2023 were selected as the study objects, and were divided into the control group (conventional balloon interventionization angioplasty) and the observation group (PCB interventionization angioplasty), with 70 cases in each group according to the differences in previous balloon interventionization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!