Enzymatic Oxydate-Triggered Self-Illuminated Photoelectrochemical Sensing Platform for Portable Immunoassay Using Digital Multimeter.

Anal Chem

Key Laboratory of Analysis and Detection for Food Safety (MOE & Fujian Province), Institute of Nanomedicine and Nanobiosensing, Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China.

Published: March 2016

Herein a novel split-type photoelectrochemical (PEC) immunosensing platform was designed for sensitive detection of low-abundance biomarkers (prostate-specific antigen, PSA, used in this case) by coupling a peroxyoxalate chemiluminescence (PO-CL) self-illuminated system with digital multimeter (DMM) readout. The PEC detection device consisted of a capacitor/DMM-joined electronic circuit and a PO-CL-based self-illuminated cell. Initially, reduced graphene oxide-doped BiVO4 (BiVO4-rGO) photovoltaic materials with good photoelectric properties was integrated into the capacitor/DMM-joined circuit for photocurrent generation in the presence of hydrogen peroxide (H2O2, as the hole-trapping reagent). A sandwich-type immunoreaction with target PSA was carried out in capture antibody-coated microplates by using glucose oxidase/detection antibody-conjugating gold nanoparticle (pAb2-AuNP-GOx). Accompanying the sandwiched immunocomplex, the labeled GOx could oxidize glucose to produce H2O2. The as-generated H2O2 could act as the coreaction reagent to trigger the chemiluminescence of the peroxyoxalate system and the PEC reaction of the BiVO4-rGO. Meanwhile, the self-illuminated light could induce photovoltaic material (BiVO4-rGO) to produce a voltage that was utilized to charge an external capacitor. With the switch closed, the capacitor could discharge through the DMM and provide an instantaneous current. Different from conventional PEC immunoassays, the as-generated photoelectron was stored in the capacitor and released instantaneously to amplify the photocurrent. Under the optimal conditions, the transient current increased with the increasing target PSA concentration in the dynamic working range from 10 pg mL(-1) to 80 ng mL(-1) with a detection limit (LOD) of 3 pg mL(-1). This work demonstrated for the first time that the peroxyoxalate CL system could be used as a suitable substitute of physical light source to apply in PEC immunoassay. In addition, this methodology afforded good reproducibility, precision, and high specificity, and the method accuracy matched well with the commercial PSA ELISA kit. Importantly, the developed split-type photoelectrochemical immunoassay could not only avoid the interfering of the biomolecules relative to the photovoltaic materials but also eliminate the need of an exciting light source and expensive instrumentation, thus representing a user-friendly and low-cost assay protocol for practical utilization in quantitative low-abundance proteins.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.6b00262DOI Listing

Publication Analysis

Top Keywords

digital multimeter
8
split-type photoelectrochemical
8
photovoltaic materials
8
target psa
8
peroxyoxalate system
8
light source
8
pec
5
enzymatic oxydate-triggered
4
self-illuminated
4
oxydate-triggered self-illuminated
4

Similar Publications

Triple Helix Molecular Switch Cascade Multiple Signal Amplification Strategies for Ultrasensitive Chloramphenicol Detection.

Anal Chem

December 2024

Molecular Science and Biomedicine Laboratory, State Key Laboratory for Chemo/Bio-Sensing and Chemometrics, College of Material Science and Engineering, College of Chemistry and Chemical Engineering, Hunan University, Changsha, Hunan410082, China.

Article Synopsis
  • A novel self-powered biosensor has been created to detect chloramphenicol (CAP) using a unique triple helix molecular switch (THMS) and DNA walkers for enhanced signal amplification.
  • The biosensor employs a CAP aptamer that binds to CAP in the presence of the target, triggering a sequence of signal releases and structural changes in the DNA walker system.
  • With a detection limit of 0.012 fM, this biosensor demonstrates high sensitivity for CAP detection in milk, along with excellent selectivity, stability, and reproducibility.
View Article and Find Full Text PDF

Portable self-powered electrochemical aptasensor for ultrasensitive and real-time detection of microcystin-RR based on hydrovoltaic-photothermal coupling effect.

Biosens Bioelectron

January 2025

Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, Jiangsu, 213164, PR China. Electronic address:

Coupling different energy harvesting technologies to obtain an excellent output signal is essential for the development of high-performance self-powered electrochemical sensors. Herein, a novel hydrovoltaic-photothermal coupling self-powered electrochemical aptasensing platform was designed for sensitive detection of microcystin (MC-RR) with a digital multimeter as a direct visual readout strategy. The straightforward ultrasonic method was employed to synthesize polyaniline (PANI) and bismuth oxybromide (BiOBr) nanosheets, which were then integrated as active components in a hydrovoltaic device.

View Article and Find Full Text PDF

The amplification strategies used for self-powered biosensor based on biofuel cell (BFC-SPB) need to be further developed. Because the currently developed strategies utilized the complicated hybridization of DNA or poorly readable current signal of capacitors for amplification, which limits the practical application in public health emergencies. Here, we present a facile chemical amplification strategy for BFC-SPB.

View Article and Find Full Text PDF

Digital multimeter-based portable photoelectrochemical immunoassay with enzyme-catalyzed precipitation for screening carbohydrate antigen 125.

Anal Methods

July 2024

Fujian-Macao Science and Technology Cooperation Base of Traditional Chinese Medicine-Oriented Chronic Disease Prevention and Treatment, College of Integrative Chinese and Western Medicine, Fujian University of Traditional Chinese Medicine, Fuzhou 350112, Fujian, PR China.

The degree of the carbohydrate antigen 125 (CA-125) level in serum is positively correlated with the severity of ovarian cancer. In this study, a facile photoelectrochemical (PEC) immunoassay was devised for sensitive detection of CA-125 employing enzyme-catalyzed precipitation to weaken the photocurrent of hollow porous InO nanotubes incorporating CdS nanoparticles. Upon the addition of the target analyte, horseradish peroxidase (HRP) enriches as a result of the formation of the sandwich immunocomplex, which can catalyze the conversion of 4-chloro1-naphthol (4-CN) to benzo-4-chlorohexadienone (4-CD) employing HO as a cofactor.

View Article and Find Full Text PDF

In this study, the functionality of an elastomer composite material containing polypyrrole (PPy) as a stress sensor was evaluated. The material was prepared using the swelling method by diffusing the pyrrole monomer into the elastomer before polymerization. To achieve adequate diffusion, organic solvents with affinity for the elastomer were used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?