Biomaterial injectates are promising as a therapy for myocardial infarction to inhibit the adverse ventricular remodeling. The current study explored interrelated effects of injectate volume and infarct size on treatment efficacy. A finite element model of a rat heart was utilized to represent ischemic infarcts of 10%, 20%, and 38% of left ventricular wall volume and polyethylene glycol hydrogel injectates of 25%, 50%, and 75% of the infarct volume. Ejection fraction was 49.7% in the healthy left ventricle and 44.9%, 46.4%, 47.4%, and 47.3% in the untreated 10% infarct and treated with 25%, 50%, and 75% injectate, respectively. Maximum end-systolic infarct fiber stress was 41.6, 53.4, 44.7, 44.0, and 45.3 kPa in the healthy heart, the untreated 10% infarct, and when treated with the three injectate volumes, respectively. Treating the 10% and 38% infarcts with the 25% injectate volume reduced the maximum end-systolic fiber stress by 16.3% and 34.7% and the associated strain by 30.2% and 9.8%, respectively. The results indicate the existence of a threshold for injectate volume above which efficacy does not further increase but may decrease. The efficacy of an injectate in reducing infarct stress and strain changes with infarct size. Copyright © 2016 John Wiley & Sons, Ltd.

Download full-text PDF

Source
http://dx.doi.org/10.1002/cnm.2772DOI Listing

Publication Analysis

Top Keywords

injectate volume
12
hydrogel injectates
8
myocardial infarction
8
infarct size
8
25% 50%
8
50% 75%
8
untreated 10%
8
10% infarct
8
infarct treated
8
maximum end-systolic
8

Similar Publications

Purpose: To utilize optical coherence tomography (OCT) and SS-OCT angiography (SS-OCTA) for quantifying morphological changes seen in eyes with recalcitrant neovascular age-related macular degeneration (nAMD) transitioned to intravitreal faricimab injections during the manufacturer's recommended induction phase of treatment.

Methods: Fifty-four treatment-recalcitrant patients (60 eyes) were recruited. OCT and SS-OCTA images were obtained at 0 and 3 months.

View Article and Find Full Text PDF

An understanding of intracellular mechanisms by which fentanyl and other synthetic opioids exert adverse effects on breathing is needed. Using freely moving adult male guinea pigs, we administered the nitric oxide synthase (NOS) inhibitor, L-NAME (N-nitro-L-arginine methyl ester), to determine whether nitrosyl factors, such as nitric oxide and S-nitrosothiols, play a role in fentanyl-induced respiratory depression. Ventilatory parameters were recorded by whole body plethysmography to determine the effects of fentanyl (75 μg/kg, IV) in guinea pigs that had received a prior injection of vehicle (saline), L-NAME or the inactive D-isomer, D-NAME (both at 50 μmol/kg, IV), 15 min beforehand.

View Article and Find Full Text PDF

Development and validation of a high-performance liquid chromatography method with fluorescence detection for the quantification of the resistance protein P-gp in cancer cells.

J Chromatogr B Analyt Technol Biomed Life Sci

January 2025

Université Clermont Auvergne, Institut Universitaire de Technologie, UMR INSERM-UCA, U1240, Imagerie Moléculaire et Stratégies Théranostiques (IMoST), 5 Avenue Blaise Pascal, 63000 Clermont-Ferrand, France.

A method using high-performance liquid chromatography coupled with fluorescence detection (HPLC-FLD) was developed and validated to quantify the innovative tool LightSpot®-FL-1, a selective permeability-glycoprotein (P-gp)-targeted fluorescent conjugate used to measure P-gp expression in cell samples. Quantifying P-gp is a major challenge in oncology as its overexpression in many cancer cells results in Multidrug Resistance (MDR) associated with chemotherapy failure. To develop the method reported herein, both sample preparation and analysis parameters were investigated.

View Article and Find Full Text PDF

(L.) Jacq. has anti-inflammatory, analgesic, haemostatic and antioxidant effects, but its pharmacological components are still unclear.

View Article and Find Full Text PDF

The Bohai oilfield is characterized by severe heterogeneity and high average permeability, leading to a low water flooding recovery efficiency. Polymer flooding only works for a certain heterogeneous reservoir. Therefore, supplementary technologies for further enlarging the swept volume are still necessary.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!