Download full-text PDF

Source

Publication Analysis

Top Keywords

[osteosynthesis anatomical
4
anatomical neck
4
neck fracture-dislocation
4
fracture-dislocation head
4
head humerus]
4
[osteosynthesis
1
neck
1
fracture-dislocation
1
head
1
humerus]
1

Similar Publications

Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.

Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.

View Article and Find Full Text PDF

Background: There has been an increase in both primary anatomic (aTSA) and reverse total shoulder arthroplasty (rTSA) over the last decade, with rates peaking for patients aged 75 years and older. Despite aTSA being the mainstay of treatment for patients with glenohumeral arthritis in the absence of rotator cuff insufficiency, there has been an upward trend of rTSA utilization in the elderly due to concerns about rotator cuff integrity, regardless of deformity. The purpose of this study is to evaluate outcomes including pain, function, range of motion, satisfaction, and complications in patients 80 years or older following primary anatomic and reverse total shoulder arthroplasty for osteoarthritis without full thickness rotator cuff tears.

View Article and Find Full Text PDF

Clinical Efficacy of Three-Dimensional-Printed Pure Titanium Fracture Plates with Locking Screw Systems in Distal Tibia Fractures.

Medicina (Kaunas)

January 2025

Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.

Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.

View Article and Find Full Text PDF

A basicervical femoral fracture is a relatively uncommon type of proximal femoral fracture. However, as the proportion of proximal femoral fractures rises in conjunction with the aging of society, the absolute number of patients with basicervical femoral fractures is also increasing. Nevertheless, the optimal surgical methods for the treatment of basicervical femoral fractures remain a topic of debate.

View Article and Find Full Text PDF

Lisfranc Fracture-dislocation With Extensor Hallucis Brevis Tendon Interposition: A Case Report.

JBJS Case Connect

January 2025

Department of Orthopaedic Surgery, Nemours Children's Health, Wilmington, Delaware.

Case: A 14-year-old adolescent girl sustained a Lisfranc fracture-dislocation with an interposed extensor hallucis brevis (EHB) tendon. Following multiple failed attempts at closed reduction in both the emergency department and the operating room, the patient was treated in a staged manner with temporizing closed reduction and percutaneous pinning in improved alignment, followed by definitive open reduction and internal fixation once soft tissues allowed.

Conclusions: Anatomic reduction and stable fixation of Lisfranc injuries is vital to regain stability and reduce the risk of midfoot arthritis and collapse.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!