Background: The use of an implantable cardioverter defibrillator (ICD) is a widely used and effective therapy, which reduces the risk of cardiac death in many cardiac diseases, both implanted for secondary and primary prevention. However, recurrent arrhythmias and ICD discharges have adverse prognostic significance. Additional parameters that would identify patients who are at increased risk of arrhythmias and appropriate ICD interventions would be of clinical value. Modern ICDs are relatively complex devices with a number of functions, including the possibility to perform noninvasive programmed stimulation (NIPS) with an implanted electrode located in the right ventricle.

Methods/design: The aim of the study is to evaluate the usefulness of NIPS in determining the likelihood of life-threatening arrhythmic events in patients with ICD. The study will include 150 consecutive patients with an ICD implanted both for primary and secondary prevention, regardless of etiology, who are followed in the outpatient clinic of our center and do not meet the exclusion criteria. A 12-step St. George's Hospital NIPS protocol using ICD will be performed. The endpoint is to induce sustained ventricular arrhythmia (VT lasting more than 30 seconds or hemodynamically unstable VT/VF) or the end of the protocol. In case of serious and/or hemodynamically unstable heart rhythm disorders resistant to treatment with a low-energy antiarrhythmic pacing (ATP), the patient receives a short-term intravenous general anesthesia, and internal or external defibrillation is performed. Outpatient follow-up will be conducted during the pre-scheduled ICD control visits. An analysis of records of a registered memory device will be collected, a patient will be interviewed, and physical examination will be carried out. The follow-ups will be held every 3 months for 1 year. The primary endpoint of the follow-up will be appropriate intervention of ICD or sudden cardiac (arrhythmic) death; the secondary, appropriate ICD intervention, or death from cardiovascular causes; and the tertiary, appropriate ICD intervention, death or hospitalization for cardiovascular causes.

Discussion: It is expected that appropriate ICD interventions during follow-up will occur more often in patients who had sustained ventricular arrhythmias induced during NIPS.

Clinical Trials Registry: ClinicalTrials.gov, NCT02373306 , date of registration: 26 February 2015.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4729177PMC
http://dx.doi.org/10.1186/s13063-016-1170-2DOI Listing

Publication Analysis

Top Keywords

appropriate icd
16
follow-up will
12
icd
11
will
9
programmed stimulation
8
cardioverter defibrillator
8
icd interventions
8
patients icd
8
sustained ventricular
8
hemodynamically unstable
8

Similar Publications

Introduction: Early antibiotic administration is one of the core treatments of sepsis which associated with reduced mortality rate. However, the appropriate timing of antibiotics remains a controversial issue, especially in patients without septic shock. Here, we reported the outcomes of early antibiotic administration within one hour from the time of infection suspicion in a tertiary care hospital.

View Article and Find Full Text PDF

Background: The evidence in the primary prevention of sudden cardiac death (SCD) by using implantable cardioverter defibrillators (ICD) in patients with ischemic cardiomyopathy (ICM) is well-established but remains controversial for those with nonischemic cardiomyopathy (NICM). This study evaluates whether prognostic differences exist between ICM and NICM patients after ICD implantation.

Methods: Patients initially undergoing ICD implantation as primary SCD prevention were retrospectively enrolled from January 2017 to May 2023.

View Article and Find Full Text PDF

Background: In cases of electrical storm, identifying the etiology is essential, as patients with reversible causes do not benefit from implantable cardioverter defibrillator (ICD). Given the diversity of pharmacologic and nonpharmacologic management tools available for hemodynamically unstable patients in electrical storm, all must be considered and tailored to each individual patient.

Case Description: This report describes a 36-year-old female without prior cardiac history who presented in ventricular fibrillation (VF) electrical storm.

View Article and Find Full Text PDF

Psychometric Properties of the Persian Version of PID5BF + M in Iranian Drug Users.

Personal Ment Health

February 2025

Department of Addiction, School of Behavioral Sciences and Mental Health (Tehran Institute of Psychiatry), Iran University of Medical Sciences, Tehran, Iran.

Background: This study aimed to adapt and evaluate the psychometric properties of the PID5BF + M as a brief measure for assessing DSM-5 and ICD-11 personality disorder traits in Iranian drug users. The sample consisted of 380 participants, including both clinical (28.68%) and nonclinical (71.

View Article and Find Full Text PDF

Study Objectives: This study assessed the utilization of potentially inappropriate medications (PIM) including oral sedative-hypnotic and atypical antipsychotic (OSHAA), healthcare resource utilization (HCRU), and costs among elderly individuals with insomnia and in the subpopulation with Alzheimer's Disease (AD) who also had a diagnosis of insomnia.

Methods: Using claims database containing International Classification of Diseases, 10th Revision (ICD-10) codes, the cohort included individuals aged ≥ 65 with incident insomnia (EI, N=152,969) and AD insomnia subpopulation (ADI, N=4,888). Proportion of patients utilizing atypical antipsychotics or oral sedative-hypnotic medications, namely z-drugs, benzodiazepines, doxepin, Dual Orexin Receptor Antagonists (DORAs), and melatonin agonists, were assessed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!