Purpose: Breast augmentation is one of the most popular cosmetic surgeries worldwide. The aim of this study is to investigate the effect of breast implant insertion on the detectability and visibility of lesions on mammography and breast tomosynthesis (BT) images.
Materials And Methods: Three software phantoms, composed of a homogeneous background with embedded silicone gel structures, and two types of breast abnormalities, microcalcifications (µCs) and masses, were generated. Two X-ray breast imaging modalities were simulated: mammography and BT with six incident monochromatic X-ray beams with energies in the interval between 20 and 30 keV. Projection images were generated using an in-house developed Monte Carlo simulator. The detectability of mammographic findings adjacent to the implant material and the influence of the incident beam energy and implant thickness on the feature detection were studied.
Results: It was found that implants thicker than 26 mm for the case of mammography and 14 mm for the case of BT obscured the visibility of underlying structures. Although BT demonstrated a lack of contrast, this modality was able to visualize µCs under considerable depths of implant. Increasing the incident beam energy led to better visualization of small µCs, while in the case of breast masses, their detectability was limited.
Conclusions: Silicone gel implants introduce a limitation in the image quality of mammograms resulting in low detectability of features. In addition, silicone gel implants obscure partially or totally parts of the image, depending on the size and the thickness of the implant as well the energy of the X-rays used.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejmp.2016.01.478 | DOI Listing |
Front Robot AI
January 2025
School of Engineering, Institute of Science Tokyo, Tokyo, Japan.
Animal muscles have complex, three-dimensional structures with fibers oriented in various directions. The tongue, in particular, features a highly intricate muscular system composed of four intrinsic muscles and several types of extrinsic muscles, enabling flexible and diverse movements essential for feeding, swallowing, and speech production. Replicating these structures could lead to the development of multifunctional manipulators and advanced platforms for studying muscle-motion relationships.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
Key Laboratory of Organosilicon Chemistry and Material Technology, College of Material, Chemistry and Chemical Engineering, Ministry of Education, Hangzhou Normal University, Hangzhou 311121, China.
A series of Si-H- or Si-Vi-terminated, branched and linear oligomers containing MeSiO segments were prepared by equilibrium polymerization or non-equilibrium polymerization initiated by living anions, respectively. These oligomers were used to improve the defects of concentrated crosslinking points and the high hardness of crosslinked products when using phenyltris(dimethylsiloxy)silane or 1,1,5,5-tetramethyl-3,3-diphenyl trisiloxane as crosslinking agents in the preparation of silicone gel. NMR, FT-IR, and GPC characterized the structure and molecular weight information of the prepared oligomers.
View Article and Find Full Text PDFMolecules
December 2024
Key Laboratory of Advanced Materials of Ministry of Education of China, Department of Chemical Engineering, Tsinghua University, Beijing 100084, China.
Waterborne polyurethane, with a mechanical strength comparable to solvent-based types, is eco-friendly and safe, using water as a dispersion medium. Polyacrylate excels in film formation and weather resistance but suffers from "hot stickiness and cold brittleness". Merging polyurethane and polyacrylate creates advanced hybrids, while organosilicon enhances properties but is restricted due to hydrolytic crosslinking.
View Article and Find Full Text PDFJ Anaesthesiol Clin Pharmacol
July 2024
Department of Anesthesia, ILBS, New Delhi, India.
BMJ Case Rep
January 2025
General Surgery, Universidade de Lisboa Faculdade de Medicina, Lisboa, Portugal.
We report a case of a woman in her late 40s with a history of breast implant surgery following breast cancer treatment. She presented with asymmetrical breast enlargement, palpable contralateral axillary lymph nodes and cutaneous nodules on both forearms. In addition, imaging evaluation revealed intracapsular implant rupture, ipsilateral internal mammary enlarged lymph nodes and multiple mediastinal lymphadenopathies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!