A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Interlaboratory Evaluation of Ultraviolet Radiation Emissions from Compact Fluorescent Lamps. | LitMetric

There have been many recent reports regarding the potential risks of UV emissions from compact fluorescent lamps (CFLs). In some of these reports, the robustness of the measurements was difficult to discern. We conducted round-robin measurements, involving three lamp manufacturers and two government research laboratories to gather reliable data on the UV emissions from commercially available CFLs. The initial sample of lamps consisted of 71 spiral-shaped CFLs purchased from local retailers. From the initial sample, 14 "high UV emitting" CFLs were chosen for further evaluation. We compared the UV emissions at a distance of 20 cm with the UV exposure limits (ELs) published by the International Commission on Non-ionizing Radiation Protection (ICNIRP). We found that the allowable exposure time for measured lamps ranged from 21 to 415 h. This indicates that the emissions would not exceed the short-term ELs that have been established by the ICNIRP for healthy individuals. We also evaluated the potential long-term risk and found it to be insignificant. There was a large variation in the UV emissions found, even for lamps from a single package, indicating that it is impossible to predict the UV output of a CFL based on its physical appearance and model designation.

Download full-text PDF

Source
http://dx.doi.org/10.1111/php.12573DOI Listing

Publication Analysis

Top Keywords

emissions compact
8
compact fluorescent
8
fluorescent lamps
8
initial sample
8
emissions
6
lamps
5
interlaboratory evaluation
4
evaluation ultraviolet
4
ultraviolet radiation
4
radiation emissions
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!