Introduction: Many low- and middle-income countries (LMICs) have enacted legislation banning smoking in public places, yet enforcement remains challenging. The aim of this study was to assess the feasibility of using a validated low-cost methodology (the Dylos DC1700) to provide objective evidence of smoke-free (SF) law compliance in hospitality venues in urban LMIC settings, where outdoor air pollution levels are generally high.
Methods: Teams measured indoor fine particulate matter (PM2.5) concentrations and systematically observed smoking behavior and SF signage in a convenience sample of hospitality venues (bars, restaurants, cafes, and hotels) covered by existing SF legislation in Mexico, Pakistan, Indonesia, Chad, Bangladesh, and India. Outdoor air PM2.5 was also measured on each sampling day.
Results: Data were collected from 626 venues. Smoking was observed during almost one-third of visits with substantial differences between countries-from 5% in India to 72% in Chad. After excluding venues where other combustion sources were observed, secondhand smoke (SHS) derived PM2.5 was calculated by subtracting outdoor ambient PM2.5 concentrations from indoor measurements and was, on average, 34 µg/m(3) in venues with observed smoking-compared to an average value of 0 µg/m(3) in venues where smoking was not observed (P < .001). In over one-quarter of venues where smoking was observed the difference between indoor and outdoor PM2.5 concentrations exceeded 64 µg/m(3).
Conclusions: This study suggests that low-cost air quality monitoring is a viable method for improving knowledge about environmental SHS and can provide indicative data on compliance with local and national SF legislation in hospitality venues in LMICs.
Implications: Air quality monitoring can provide objective scientific data on SHS and air quality levels in venues to assess the effectiveness of SF laws and identify required improvements. Equipment costs and high outdoor air pollution levels have hitherto limited application in LMICs. This study tested the feasibility of using a validated low-cost methodology in hospitality venues in six LMIC urban settings and suggests this is a viable method for improving knowledge about SHS exposure and can provide indicative data on compliance with SF legislation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ntr/ntv290 | DOI Listing |
Heliyon
January 2025
School of Architecture, Tianjin University, 300072, Tianjin, China.
Air pollution has become a major challenge to global urban sustainable development, necessitating urgent solutions. Meteorological variables are key determinants of air quality; however, research on their impact across different urban gradients remains limited, and their mechanisms are largely unexplored. This study investigates the dynamic effects of meteorological variables on air quality under varying levels of urbanization using Kaohsiung City, Taiwan, as a case study.
View Article and Find Full Text PDFIndian J Occup Environ Med
December 2024
Department of Electronics, Sri Venkateswara College, University of Delhi, New Delhi, India.
Introduction: Construction sites generate high levels of air pollution, contributing to more than 4% of particulate matter in the atmosphere. Literature indicates that on-site pollution is an important factor that contributes to lung impairments in construction workers. Chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ADRS) are known to be exacerbated because of exposure to a variety of construction pollutants mainly particulate matter (PM10, PM2.
View Article and Find Full Text PDFConnecting changes in emissions to air quality is critical for evaluating the effects of a specific policy. Here, we introduce a methodology to aid in assessing the air quality impacts of changes in the energy system. A set of widely varying scenarios that describe alternative potential evolutions of the US energy system is constructed using the TIMES energy system model.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
January 2025
Shandong University of Science and Technology, Institute of Carbon Neutrality, College of Chemical and Biological Engineering, No 579 Qianwangang Road, Huangdao District, 266590, Qingdao, CHINA.
Traditionally weak buried interaction without customized chemical bonding always goes against the formation of high-quality perovskite film that highly determines the efficiency and stability of perovskite solar cells. To address this issue, herein, we propose a bimolecular nucleophilic substitution reaction (SN2) driving strategy to idealize the robust buried interface by simultaneously decorating underlying substrate and functionalizing [PbX6]4- octahedral framework with iodoacetamide and thiol molecules, respectively. Theoretical and experimental results demonstrate that a strong SN2 reaction between exposed halogen and thiol group in two molecules occurs, which not only benefits the reinforcement of buried adhesion, but also triggers target-point-oriented crystallization, synergistically upgrading the upper perovskite film quality and accelerating interfacial charge extraction-transfer behavior.
View Article and Find Full Text PDFInt J Environ Health Res
January 2025
School of Public Health, The Key Laboratory of Environmental Pollution Monitoring and Disease Control, Ministry of Education, Guizhou Medical University, Guiyang, China.
Myocardial infarction (MI) ranks as one of the primary causes of global disabilities and disease deaths. The association between fine particulate matter (PM2.5) and MI has gained attention in recent years.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!