A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of Sodium Tanshinone IIA Sulfonate in human plasma by LC-MS/MS and its application to a clinical pharmacokinetic study. | LitMetric

Determination of Sodium Tanshinone IIA Sulfonate in human plasma by LC-MS/MS and its application to a clinical pharmacokinetic study.

J Pharm Biomed Anal

Department of Cardiology, Huashan Hospital, Fudan University, 12 Wulumuqi Middle Road, Shanghai 200040, China. Electronic address:

Published: March 2016

AI Article Synopsis

  • A new assay using protein precipitation and liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been created and tested for measuring Sodium Tanshinone IIA Sulfonate (STS) in human plasma.
  • The process involves adding an internal standard (DHEAS-D5) and using a specific mixture of acetonitrile and methanol for sample preparation, followed by detection through a specialized mass spectrometer.
  • The method shows high accuracy and precision, with a calibration range of 2-1000 ng/mL and has been successfully used in a pharmacokinetic study with male volunteers in China.*

Article Abstract

An assay based on protein precipitation and liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of Sodium Tanshinone IIA Sulfonate (STS) in human plasma. After the addition of dehydroepiandrosterone-D5-3-sulfate sodium salt (DHEAS-D5) as internal standard (IS) and formic acid, plasma samples were prepared by one-step protein precipitation with a mixture of acetonitrile and methanol. Isocratic mobile phase consisted of 0.4 mmol/L ammonium formate buffer (16 ppm formic acid)/acetonitrile (40/60, v/v) on a XSELECT™ HSS T3 column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 373.3→357.1 for STS and m/z 373.0→97.8 for the IS. Calibration curves of STS in human plasma were linear (r=0.9957-0.9998) over the concentration range of 2-1000 ng/mL with acceptable accuracy and precision. The lower limit of quantification in human plasma was 2 ng/mL. The validated LC-MS/MS method has been successfully applied to a pharmacokinetic study of STS in Chinese healthy male volunteers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2016.01.026DOI Listing

Publication Analysis

Top Keywords

human plasma
16
sodium tanshinone
8
tanshinone iia
8
iia sulfonate
8
pharmacokinetic study
8
protein precipitation
8
sts human
8
plasma
5
determination sodium
4
human
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!