A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Monte Carlo derivation of filtered tungsten anode X-ray spectra for dose computation in digital mammography. | LitMetric

Monte Carlo derivation of filtered tungsten anode X-ray spectra for dose computation in digital mammography.

Radiol Bras

D.Sc., Titular Researcher-Professor, Centro de Desenvolvimento da Tecnologia Nuclear / Comissão Nacional de Energia Nuclear (CDTN/CNEN), Departamento de Engenharia Nuclear da Universidade Federal de Minas Gerais (DEN-UFMG), Belo Horizonte, MG, Brazil.

Published: January 2016

Objective: Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations.

Materials And Methods: Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode.

Results: Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%.

Conclusion: The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4725397PMC
http://dx.doi.org/10.1590/0100-3984.2014.0108DOI Listing

Publication Analysis

Top Keywords

monte carlo
16
filtered tungsten
12
x-ray spectra
12
hvl values
12
tungsten anode
8
anode x-ray
8
digital mammography
8
filtered spectra
8
compared experimentally
8
calculated hvl
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!