The Mechanics of Brow-Suspension Ptosis Repair: A Comparative Study of Fox Pentagon and Crawford Triangle Techniques.

Ophthalmic Plast Reconstr Surg

*Department of Mechanical Engineering, University College London, Torrington Place, London, United Kingdom; †Department of Materials Science and Metallurgy, Cambridge Centre for Medical Materials, University of Cambridge, Cambridge, United Kingdom; ‡BMI Goring Hall Hospital, West Sussex, United Kingdom; and §UCL Institute of Ophthalmology NIHR Biomedical Research Centre for Ophthalmology, London, United Kingdom.

Published: March 2017

Purpose: To perform quantitative analysis of the most commonly used brow-suspension configurations.

Methods: The inflection positions for Fox pentagon and Crawford triangle configurations were marked on 49 healthy volunteers (male and female) and photographs taken in 3 states: "normal," "closed," and "raised." The skin marks were measured vectorially with respect to the medial canthus, and displacement changes were evaluated for "normal-to-closed" ("blinking") and from "closed-to-raised" ("eye-opening") states. The distance between a pair of inflection marks, representing the approximate path of sling configurations, were also measured and analyzed in relation to the mechanical properties of a variety of synthetic brow-suspension materials.

Results: "Blinking" resulted in the greatest displacement in the medial eyelid incision, resulting in the greatest strain on the line connecting the medial eyelid and medial brow inflections. No significant differences in the strains for individual lines were found between the Fox and Crawford techniques, although the former shows a significantly lower overall strain in the whole loop than the latter. The displacements of some inflections and of the strains of a few lines differed significantly in men and women.

Conclusions: Within the scope of this study, the blinking action was shown to result in the maximum strain of ~40%, which lies within the elastic region of stress-strain curves for some commonly used synthetic brow-suspension materials. No one method was statistically superior, although the Fox pentagon gave a significantly lower overall strain when the sling material was assumed to move somewhat around the inflections within a closed loop.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IOP.0000000000000621DOI Listing

Publication Analysis

Top Keywords

fox pentagon
12
pentagon crawford
8
crawford triangle
8
synthetic brow-suspension
8
medial eyelid
8
lower strain
8
mechanics brow-suspension
4
brow-suspension ptosis
4
ptosis repair
4
repair comparative
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!