Introduction: In this study we investigated non-invasive, effort-independent measurement of ventilatory mechanics in patients with amyotrophic lateral sclerosis (ALS).
Methods: Ventilatory mechanics were measured by optoelectronic plethysmography (OEP) in ALS patients and matched controls. Analysis determined whether OEP measurements correlated with standard clinical measures.
Results: ALS patients (N = 18) had lower forced vital capacity percent predicted (55.2 ± 22.0 L) compared with controls (N = 15; 104.7 ± 16.2 L) and higher ventilatory inefficiency (49.2 ± 9.0 vs. 40.0 ± 3.5, respectively; P < 0.001 for both measures). Lower tidal volumes within the diaphragm area correlated with the dyspnea subscore calculated from the ALS Functional Rating Scale-revised (P = 0.031), and paradoxical movement of the ribcage compared with the abdominal compartment was seen in the most severe cases.
Conclusions: Evaluation of ventilatory mechanics in mild to severe ALS reveals dysfunction that is not readily detected by standard testing and ALS functional severity assessment measures. Muscle Nerve 54: 270-276, 2016.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mus.25043 | DOI Listing |
Eur J Pediatr
January 2025
Hospital de Clinicas de Porto Alegre, Rua Silva Jardim 1155 # 701, Porto Alegre, RS, 90450-071, Brazil.
Unlabelled: To evaluate the accuracy of the lung ultrasound score (LUS) in predicting ventilatory weaning failure during neonatal hospitalization in the NICU and to identify factors associated with weaning failure, including corrected gestational age (CGA). This prospective, longitudinal, pragmatic and observational cohort study included neonates on mechanical ventilation for at least 48 h. The primary outcome was the accuracy of lung ultrasound in predicting 3-day weaning failure, with the ROC curve used to determine the best LUS cutoff (sensitivity and specificity).
View Article and Find Full Text PDFCrit Care Explor
January 2025
Department of Mathematics and School of Biomedical Engineering, Colorado State University, Fort Collins, CO.
The purpose of this work is to evaluate the feasibility of lung imaging using 3D electrical impedance tomography (EIT) during spontaneous breathing trials (SBTs) in patients with acute hypoxic respiratory failure. EIT is a noninvasive, nonionizing, real-time functional imaging technique, suitable for bedside monitoring in critically ill patients. EIT data were collected in 24 mechanically ventilated patients immediately preceding and during a SBT on two rows of 16 electrodes using a simultaneous multicurrent source EIT system for 3D imaging.
View Article and Find Full Text PDFMed Sci Sports Exerc
November 2024
Department of Biomedical Sciences for Health, Università degli Studi di Milano, ITALY.
Purpose: Cigarette smoking (CS) induces systemic changes that impair cardiorespiratory and muscular function both at rest and during exercise. Although these abnormalities are reported in sedentary, middle-aged smokers (SM) with pulmonary disease, few and controversial studies focused on young, physically active SM at the early stage of smoking history. This study aimed at assessing the impact CS on cardiorespiratory and metabolic response during an incremental test and the subsequent recovery in young, physically active SM without known lung or cardiovascular disease.
View Article and Find Full Text PDFAnn Intensive Care
January 2025
Jiangsu Provincial Key Laboratory of Critical Care Medicine, Department of Critical Care Medicine, Zhongda Hospital, School of Medicine, Southeast University, No. 87, Dingjiaqiao Road, Gulou District, Nanjing, 210009, People's Republic of China.
Background: The association between bedside ventilatory parameters-specifically arterial carbon dioxide pressure (PaCO) and ventilatory ratio (VR)-and mortality in patients with acute respiratory distress syndrome (ARDS) remains a topic of debate. Additionally, the persistence of this association over time is unclear. This study aims to investigate the relationship between 28-day mortality in ARDS patients and their longitudinal exposure to ventilatory inefficiency, as reflected by serial measurements of PaCO and VR.
View Article and Find Full Text PDFCrit Care Explor
January 2025
Department of Mathematics and School of Biomedical Engineering, Colorado State University, Fort Collins, CO.
The purpose of this work is to evaluate the feasibility of lung imaging using 3D electrical impedance tomography (EIT) during spontaneous breathing trials (SBTs) in patients with acute hypoxic respiratory failure. EIT is a noninvasive, nonionizing, real-time functional imaging technique, suitable for bedside monitoring in critically ill patients. EIT data were collected in 24 mechanically ventilated patients immediately preceding and during a SBT on two rows of 16 electrodes using a simultaneous multicurrent source EIT system for 3D imaging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!