A new method to measure the distance among scatters, the density of scatters, and the scatters' diameter in artificial composite materials has been proposed. This method is based on detecting the reflection amplitude change (amp) of the echo signal reflected from scatters. Simulation results show that such a method is valid for the distance less than four times of the acoustic wavelength, because the coupling between the scatters can be neglected for the distance larger than four times of the acoustic wavelength. Therefore, this new measure method can be always valid by choosing appropriate frequency according to the scaling rule discussed in this paper. At the same time, it is found that the diameter of scatters is the half of the wavelength where the curve peak of the amp vs frequency occurs. It implies that such a new method can also be used to measure the diameter of scatters in solids and liquids, and even in PM2.5 pollution particles in air.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultras.2016.01.002 | DOI Listing |
Psychother Res
January 2025
Department of Psychology, University of Kansas, Lawrence, KS, USA.
Background: This special section underscores the potential of multimodal measurement approaches to transform psychotherapy research. A multimodal approach provides a more comprehensive understanding than any single modality (type of collected information) can provide on its own.
Methods: Traditionally, clinicians and researchers have relied on their intuition, experience, and training to integrate different types of information in a psychotherapy session/treatment.
Endocrine
January 2025
Department of Endocrinology and Metabolic Diseases, Manisa Celal Bayar University Hospital, Manisa, Turkey.
Purpose: Our study evaluated skeletal muscle mass, function and quality among mild autonomous cortisol secretion (MACS) patients and non-functioning adrenal incidentaloma (NFAI) patients in comparison with the control group without adrenal mass.
Methods: 63 NFAI (49 female, 14 male) and 31 MACS (24 female, 7 male) patients were included in the study. As the control group, 44 patients (31 women, 13 men) who were known to have no radiological adrenal pathology on computed tomography or magnetic resonance imaging performed for other reasons were selected.
Radiol Med
January 2025
Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
Purpose: To develop an artificial intelligence (AI) algorithm for automated measurements of spinopelvic parameters on lateral radiographs and compare its performance to multiple experienced radiologists and surgeons.
Methods: On lateral full-spine radiographs of 295 consecutive patients, a two-staged region-based convolutional neural network (R-CNN) was trained to detect anatomical landmarks and calculate thoracic kyphosis (TK), lumbar lordosis (LL), sacral slope (SS), and sagittal vertical axis (SVA). Performance was evaluated on 65 radiographs not used for training, which were measured independently by 6 readers (3 radiologists, 3 surgeons), and the median per measurement was set as the reference standard.
Pediatr Surg Int
January 2025
Division of Pediatric Surgery, Department of Surgery, University of Florida College of Medicine, PO Box 100119, Gainesville, FL, 32610-0119, USA.
Purpose: Initial recommendations for ECMO had relative contraindications for low birth weight (BW) or low gestational age (GA) babies. However, more recent literature has demonstrated improved and acceptable outcomes of ECMO in smaller neonates. The purpose of this study was to understand both utilization and survival in patients with lower GA and BW.
View Article and Find Full Text PDFEJNMMI Phys
January 2025
Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden.
Background: System calibration is essential for accurate SPECT/CT dosimetry. However, count losses due to dead time and pulse pileup may cause calibration errors, in particular for I, where high count rates may be encountered. Calibration at low count rates should also be avoided to minimise detrimental effects from e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!