Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate vector analysis, rotational stability, and visual outcomes after implantation of toric IOLs with low (<2.25 diopter [D]) toric values (Acrysof IQ SN6AT3 or SN6AT4) and moderate-to-high toric (3.00 D to 6.00 D) values (Acrysof IQ SN6AT5, SN6AT6, SN6AT7, SN6AT8, or SN6AT9) versus after implantation of a nontoric IOL (Acrysof SN60WF) in eyes with regular topographic corneal astigmatism.
Setting: Department of Ophthalmology, Paracelsus Medical University Salzburg, Salzburg, Austria.
Design: Randomized controlled clinical trial.
Methods: The study included eyes of patients undergoing phacoemulsification and IOL implantation. Patients were randomized into 3 groups to bilaterally receive the nontoric IOL, the low toric IOL, or the moderate-to-high toric IOL. Over a 6-week follow-up period, rotational stability and astigmatic changes were evaluated in the 2 toric IOL groups using the Alpins vector method.
Results: The study included 78 eyes of 39 patients. Postoperatively mean refractive astigmatism decreased significantly from 1.45 D ± 1.18 (SD) to 0.36 ± 0.44 D in the low toric group and from 1.92 ± 1.09 D to 0.31 ± 0.46 D in the moderate-to-high toric group. There was no significant difference between mean difference vectors in the low toric IOL group and the moderate-to-high toric IOL group. A significant difference in the correction index was detected, revealing overcorrection with low toric IOLs (1.03 ± 0.12 D) and undercorrection with moderate-to-high toric IOLs (0.95 ± 0.12 D).
Conclusions: Implantation of low toric IOLs and medium-to-high toric IOLs in patients with low to moderate-to-high corneal astigmatism was shown to be effective in correcting regular corneal astigmatism. Undercorrection in the moderate-to-high group could be related to misalignment.
Financial Disclosure: This research project was financially supported by the Fuchs Foundation for the Promotion of Research in Ophthalmology, Salzburg, Austria. Alcon Inc. financially supports the Fuchs-Foundation as the clinical research center of the Department of Ophthalmology of the Paracelsus Medical University Salzburg, Salzburg, Austria (Grant Number 2010-37). No author has a financial or proprietary interest in any material or method mentioned.