Photogrammetric method to measure the discrepancy between clinical and software-designed positions of implants.

J Prosthet Dent

Assistant Professor, Section of Periodontology, Implantology, and Gnathology, Centre of Dentistry, University of Parma, Parma, Italy.

Published: June 2016

Statement Of Problem: The position of dental implants placed with software-guided systems should be highly accurate in order to ensure safety and a passive fit of the immediate prosthesis.

Purpose: The purpose of this study was to measure the discrepancy between the clinical and software-planned position of dental implants by applying a photogrammetric method.

Material And Methods: Two casts were obtained, 1 from the surgical template and 1 from the actual position of the implants on the alveolar ridge of a patient. Photogrammetry was then applied to precisely locate the position of each implant on the casts. Because this mathematical technique required the identification of image points and of the relative spatial coordinates, 4 marks were drilled on the implant screw. The position of the implants was then identified as the geometric center of the 4 marks, while the orientation of the implant axis was represented by a vector normal to the plane fitting the points. A series of 16 convergent images all around the object was made using a high-resolution digital camera. A mathematical method called "rototranslation" was used to superimpose the cast images for the comparison.

Results: The tests performed on the casts resulted in an average precision level of 4 μm for the locations and less than 1 degree for the axis of the implants. A series of empirical and numerical tests were performed to assess the performance of the procedure and of the measurement protocol.

Conclusions: The photogrammetric method is reproducible and can be used to measure the discrepancy between the software-planned and the real position of dental implants. Considering that the average precision level required for an implant-based prosthesis is approximately 50 μm, the error associated with this method can be considered as negligible.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2015.10.017DOI Listing

Publication Analysis

Top Keywords

measure discrepancy
12
position dental
12
dental implants
12
photogrammetric method
8
discrepancy clinical
8
position implants
8
tests performed
8
average precision
8
precision level
8
implants
7

Similar Publications

Background: Hemoglobin G-Siriraj is a rare hemoglobin variant caused by a β-globin gene mutation (HBB: c.22G>A). The focus of this paper is aimed mainly at the chromatographic and electrophoretic properties of hemoglobin G-Siriraj for a presumptive identification.

View Article and Find Full Text PDF

Objectives: Point-of-care testing available in prehospital settings requires the establishment of new medical decision points. The aim of the present work was to determine the cut-off of the lactate threshold that activates alert triggers for all-cause 2-day mortality.

Design: Multicentre, prospective, ambulance-based, observational study.

View Article and Find Full Text PDF

Aim: This study aimed to assess and identify the priority of educational needs for geriatric nursing competence among Chinese undergraduate nursing students.

Background: The increased aging population puts new challenges in geriatric nursing care. Competence in geriatric nursing is essential for nursing students to be well-equipped to be qualified nurses in their future work to meet the growing demand for geriatric nursing.

View Article and Find Full Text PDF

Objectives: C-peptide is an equimolar by-product of insulin biosynthesis. It is used clinically to assess insulin secretion and differentiate types of diabetes. However, the lack of standardization across assays limits its broader application.

View Article and Find Full Text PDF

Objective: To identify patient and provider factors associated with lower rates of follow-up for positive depression screens in outpatient settings.

Design: Retrospective cohort study with electronic health record analysis investigating factors associated with follow-up care for patients with moderate-to-severe depressive symptoms. Patient and provider variables were associated with rates of follow-up for positive depression screens.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!