A 66-year-old male, who had received renal transplantation 10 years before, was admitted to our hospital with urinary retention. The prostate volume was 169.2 ml. Furthermore, grade 5 vesicoureteral reflux (VUR) was shown in the cystography. Holmium laser enucleation of prostate (HoLEP) was performed, and percutaneous nephrostomy to the transplanted kidney was performed simultaneously to prevent from severe perioperative infection. After that, renal graft function improved and no urinary retention reoccurred, although surgical repair against VUR was necessary 10 months after HoLEP. We conclude that surgical treatment for BPH after kidney transplantation should be strongly considered with care for infections.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4719790PMC
http://dx.doi.org/10.1016/j.eucr.2015.11.003DOI Listing

Publication Analysis

Top Keywords

holmium laser
8
laser enucleation
8
enucleation prostate
8
percutaneous nephrostomy
8
nephrostomy transplanted
8
transplanted kidney
8
vesicoureteral reflux
8
urinary retention
8
prostate percutaneous
4
kidney patient
4

Similar Publications

Purpose: To compare the effect on sexual function of ejaculation-sparing enucleation of the prostate using Thulium: YAG laser (ES-ThuLEP) versus continuous-wave Thulium Fiber Laser (ES-ThuFLEP).

Methods: 112 patients with lower urinary tract symptoms secondary to benign prostatic hyperplasia who wished to preserve ejaculation were treated. 58 patients underwent ES-ThuLEP (Group A) using the Cyber TM generator.

View Article and Find Full Text PDF

Objectives: To evaluate the safety and feasibility of "en-bloc" Holmium Laser Enucleation of the Prostate (HoLEP) with trainee involvement in patients with prostates larger than 200 cc.

Patients And Methods: A retrospective analysis was conducted on patients undergoing HoLEP using the "en-bloc" technique for prostate sizes > 200 cc between July-2017 and December-2023 at an academic teaching hospital. Perioperative data was collected, including patient demographics, clinical parameters, operative details and functional outcomes.

View Article and Find Full Text PDF

A transversely isotropic diode-pumped solid-state laser is used to obtain an orthogonally dual-polarization nonplanar circular mode (NCM) under off-axis pumping in the strictly degenerate cavity. Each polarized component of the NCM outside the cavity is revealed to be individually localized on the ray orbits forming a nonplanar surface, in which the transverse patterns display multiple spots well positioned on a circular structure. An analytical representation is established to explore polarization-resolved components of the NCM by utilizing the Gaussian wave packet to directly correlate with geometrical rays.

View Article and Find Full Text PDF

We demonstrated what is believed to be the first 1.2 GHz nonlinear polarization rotation stretched-pulse mode-locked Yb:fiber laser with a compact design and innovative components. With a compact Faraday rotation angle has been used in NPR mode-locked lasers, and we find that incomplete isolation of backward-propagating light does not hinder self-starting.

View Article and Find Full Text PDF

Background: We aimed to evaluate and compare the rise in the temperature for the safety of the kidney parenchyma on firing the Holmium: Yttrium Aluminium Garnet laser and the Thulium Fiber Laser during laser lithotripsy in humans.

Method: We included 30 pre-stented patients with renal calculi undergoing Retrograde intra-renal surgery. They were randomized into two groups - 15 patients underwent holmium laser lithotripsy and 15 patients underwent TFL laser lithotripsy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!