Single-vessel, intracoronary infusion of stem cells under stop-flow conditions has proven safe but achieves only limited myocardial coverage. Continuous flow intracoronary delivery to one or more coronary vessels may achieve broader coverage for treating cardiomyopathy, but has not been investigated. Using nonocclusive coronary guiding catheters, we infused allogeneic cardiosphere-derived cells (CDCs) either in a single vessel or sequentially in all three coronary arteries in porcine ischemic cardiomyopathy and used magnetic resonance imaging (MRI) to assess structural and physiological outcomes. Vehicle-infused animals served as controls. Single-vessel stop-flow and continuous-flow intracoronary infusion revealed equivalent effects on scar size and function. Sequential infusion into each of the three major coronary vessels under stop-flow or continuous-flow conditions revealed equal efficacy, but less elevation of necrotic biomarkers with continuous-flow delivery. In addition, multi-vessel delivery resulted in enhanced global and regional tissue function compared to a triple-vessel placebo-treated group. The functional benefits after global cell infusion were accompanied histologically by minimal inflammatory cellular infiltration, attenuated regional fibrosis and enhanced vessel density in the heart. Sequential multi-vessel non-occlusive delivery of CDCs is safe and provides enhanced preservation of left ventricular function and structure. The current findings provide preclinical validation of the delivery method currently undergoing clinical testing in the Dilated cardiomYopathy iNtervention With Allogeneic MyocardIally-regenerative Cells (DYNAMIC) trial of CDCs in heart failure patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4718597 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0144523 | PLOS |
Hellenic J Cardiol
December 2024
Division of Cardiovascular Medicine, Tsuchiura Kyodo General Hospital, Ibaraki, Japan. Electronic address:
Background: Epicardial stenosis and coronary microvascular dysfunction (CMD) may coexist in patients with chronic coronary syndrome (CCS). Microvascular resistance reserve (MRR) has been demonstrated to be a valid cross-modality metric using continuous saline infusion thermodilution and intracoronary Doppler flow velocity methods. This study aimed to investigate the prevalence and diagnostic concordance of CMD defined by MRR using two methods-stress transthoracic Doppler echocardiography (S-TDE) and the invasive bolus thermodilution method (B-Thermo)-in patients with functionally significant epicardial stenosis.
View Article and Find Full Text PDFNat Commun
December 2024
Cardiovascular Research Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Adeno-associated virus-based gene therapy is a promising avenue in heart failure treatment, but has shown limited cardiac virus uptake in humans, requiring new approaches for clinical translation. Using a Yorkshire swine ischemic heart failure model, we demonstrate significant improvement in gene uptake with temporary coronary occlusions assisted by mechanical circulatory support. We first show that mechanical support during coronary artery occlusions prevents hemodynamic deterioration (n = 5 female).
View Article and Find Full Text PDFJACC Cardiovasc Interv
December 2024
Mayo Clinic, Rochester, Minnesota, USA. Electronic address:
Background: Coronary microvascular dysfunction (CMD) is a common cause of angina with no obstructive coronary artery disease (ANOCA), and effective treatment options are limited.
Objectives: This study aims to assess the safety and efficacy of the coronary sinus (CS) Reducer (Neovasc, Inc/Shockwave Medical) for treatment of angina in patients with CMD.
Methods: This Phase II trial enrolled 30 patients with ANOCA, invasively diagnosed CMD, and Canadian Cardiovascular Society (CCS) class 3 to 4 angina despite medical therapy.
Am J Cardiol
January 2025
Department of Internal Medicine, Baylor Scott and White, Temple, Texas; Division of Cardiology, Baylor Scott and White, Temple, Texas. Electronic address:
Coronary flow reserve (CFR) and index of microcirculatory resistance (IMR) obtained through coronary bolus thermodilution are used to assess and treat patients with angina and no obstructive coronary artery disease. Previous studies demonstrate comparable results assessing epicardial ischemia by fractional flow reserve using intravenous (IV) or intracoronary (IC) adenosine. It is unknown if there is a similarity between IC and IV hyperemia with adenosine when performing coronary reactivity testing (CRT).
View Article and Find Full Text PDFInt J Cardiol
January 2025
Department of Cardiology, Sixth Medical Center of Chinese PLA General Hospital, Beijing, China. Electronic address:
Background: The no-reflow phenomenon is a significant complication during excimer laser coronary angioplasty (ELCA) procedures, which can lead to adverse outcomes. This study explores the efficacy of intracoronary administration of a cocktail solution comprising nitroglycerin, heparin, and verapamil on preventing no-reflow during ELCA in patients with in-stent restenosis (ISR).
Methods: This study included patients undergoing ELCA with contrast infusion for ISR.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!