Objective: The aim of this study was to investigate the feasibility of using an inductive tongue control system (ITCS) for controlling robotic/prosthetic hands and arms.

Methods: This study presents a novel dual modal control scheme for multigrasp robotic hands combining standard electromyogram (EMG) with the ITCS. The performance of the ITCS control scheme was evaluated in a comparative study. Ten healthy subjects used both the ITCS control scheme and a conventional EMG control scheme to complete grasping exercises with the IH1 Azzurra robotic hand implementing five grasps. Time to activate a desired function or grasp was used as the performance metric.

Results: Statistically significant differences were found when comparing the performance of the two control schemes. On average, the ITCS control scheme was 1.15 s faster than the EMG control scheme, corresponding to a 35.4% reduction in the activation time. The largest difference was for grasp 5 with a mean AT reduction of 45.3% (2.38 s).

Conclusion: The findings indicate that using the ITCS control scheme could allow for faster activation of specific grasps or functions compared with a conventional EMG control scheme.

Significance: For transhumeral and especially bilateral amputees, the ITCS control scheme could have a significant impact on the prosthesis control. In addition, the ITCS would provide bilateral amputees with the additional advantage of environmental and computer control for which the ITCS was originally developed.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2016.2517742DOI Listing

Publication Analysis

Top Keywords

control scheme
32
itcs control
20
control
15
emg control
12
itcs
9
robotic hand
8
tongue control
8
scheme
8
conventional emg
8
bilateral amputees
8

Similar Publications

Relying on composite nonlinear feedback, an output-feedback controller is robustly addressed in the singular models with uncertainties, disturbances and time-delays. For this purpose, an observer-based compensator is utilized to realize the purpose. In the presence of disturbance and uncertainty, it is demonstrated that the tracking error and the states of the overall system are ultimately bounded.

View Article and Find Full Text PDF

1-year efficacy results after MR-guided risk-adapted stereotactic radiotherapy of infra-diaphragmatic oligometastases in a multicenter phase II trial.

Radiother Oncol

January 2025

Department of Oncology, Copenhagen University Hospital - Herlev and Gentofte, Borgmester Ib Juuls Vej 1, Herlev 2730 Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 3B, Copenhagen 2200, Denmark.

Background And Purpose: The SOFT (Stereotactic ablative radiotherapy of infra-diaphragmatic sOFT tissue metastases) trial assesses the safety and efficacy of risk-adapted MR-guided stereotactic ablative radiotherapy (SABR) of infra-diaphragmatic soft tissue metastasis in patients with oligometastatic disease (OMD) (clinicaltrials.gov ID NCT04407897). This paper reports the one-year efficacy analysis and evaluates associations between local control (LC) and clinical and dosimetric parameters.

View Article and Find Full Text PDF

Control Principles of Neural Dynamics Revealed by the Neurobiology of Timing.

Annu Rev Neurosci

January 2025

1Department of Brain and Cognitive Sciences, McGovern Institute for Brain Research, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA; email:

Cognition unfolds dynamically over flexible timescales. A major goal of the field is to understand the computational and neurobiological principles that enable this flexibility. Here, we argue that the neurobiology of timing provides a platform for tackling these questions.

View Article and Find Full Text PDF

The selective number-dependent arbitrary phase gates form a powerful class of quantum gates, imparting arbitrarily chosen phases to the Fock states of a cavity. However, for short pulses, coherent errors limit the performance. Here, we demonstrate in theory and experiment that such errors can be completely suppressed, provided that the pulse times exceed a specific limit.

View Article and Find Full Text PDF

Significant advancements in integrated photonics have enabled high-speed and energy efficient systems for various applications, from data communications and high-performance computing to medical diagnosis, sensing, and ranging. However, data storage in these systems has been dominated by electronic memories that in addition to signal conversion between optical and electrical domains, necessitates conversion between analog to digital domains and electrical data movement between processor and memory that reduce the speed and energy efficiency. To date, scalable optical memory with optical control has remained an open problem.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!